Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0
Previous issue date: 2009-08-21Bitstream added on 2014-06-13T19:20:06Z : No. of bitstreams: 1
rodrigues_ts_dr_araca.pdf: 439179 bytes, checksum: 176184a10c13e6ef36390b6f5b61b9de (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Proposição: Avaliar a resposta tecidual ao enxerto xenógeno inorgânico de osso bovino, por meio de análise histomorfológica e histomorfométrica. Material e método: O enxerto foi obtido da costela de boi resfriada após 8 horas de sacrifício do animal e processado da seguinte maneira: imersão por 60 minutos em água oxigenada a temperatura ambiente, com trocas a cada 15 minutos; imersão em água oxigenada aquecida, a uma temperatura de 100ºC, por 30 segundos e resfriamento imediato com água destilada a uma temperatura variando de 6º a 8ºC; enxague em água destilada corrente por 6 horas; imersão em álcool 70º, 90º e 100º, respectivamente, sendo 15 minutos em cada álcool; esterilização em autoclave. Em seguida, 10 coelhos brancos (Nova Zelândia) foram utilizados, originando dois grupos: Grupo I – enxerto inserido no pavilhão auricular e Grupo II – enxerto inserido e fixado em tíbia. Decorridos 180 dias, foi realizado sacrifício dos animais por injeção excessiva de anestésico. Resultados: No Grupo I, o enxerto apresentou-se em íntimo contato com tecido subcutâneo. No Grupo II, o enxerto apresentou-se em justaposição com o leito ósseo receptor. E nos dois grupos havia espaços medulares preenchidos por medula óssea ativa e osso neoformado, além da ausência de osteócitos no osso bovino e presença destas células no osso neoformado, próximo aos espaços medulares. Conclusão: Em razão dos resultados obtidos o enxerto xenógeno inorgânico de osso bovino demonstrou biocompatibilidade, capacidade osteocondutora e discreta perda de volume, preenchendo requisitos importantes do material ideal para reconstrução óssea. / Objective: To evaluate tissue response to inorganic bovine bone xenograft by histomorphological and histomorphometrical analyses. Material and methods: The bone grafts was obtained from cooled bovine rib 8 hours after slaughtering and were processed as follows: 60-minute immersion in hydrogen peroxide at room temperature, with changes at 15-minute intervals; 30-second immersion in hydrogen peroxide at 100ºC; immediate cooling with distilled water at temperatures ranging from 6º to 8ºC; rinsing in running distilled water for 6 hours; immersion in alcohol grades of 70º, 90º and 100ºGL (15-minute in each solution); autoclaving. Thereafter, 10 white New Zealand rabbits were distributed into two groups: Group I – graft inserted in the ear pavilion and Group II – graft inserted and fixed in the tibia. After 180 days, the animals were sacrificed by anesthetic overdose. Results: In Group I, the graft was in intimate contact with the subcutaneous tissue, while in Group II the graft was juxtaposed to the recipient site. Both groups presented medullar spaces filled with active bone marrow and newly formed bone. In addition, osteocytes were absent in the bovine bone graft and present in the newly formed bone, close to the medullar spaces. Conclusion: From the obtained results, the inorganic bovine bone xenograft showed biocompatibility.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/101051 |
Date | 21 August 2009 |
Creators | Rodrigues, Thaís da Silveira [UNESP] |
Contributors | Universidade Estadual Paulista (UNESP), Poi, Wilson Roberto [UNESP], Júnior, Idelmo Rangel Garcia [UNESP] |
Publisher | Universidade Estadual Paulista (UNESP) |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis |
Format | 58 f. : il. + 1 CD-ROM |
Source | Aleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP |
Rights | info:eu-repo/semantics/openAccess |
Relation | -1, -1, -1 |
Page generated in 0.0021 seconds