Return to search

A influÃncia da incisÃo para-areolar no quadrante superior externo da mama, na localizaÃÃo do linfonodo sentinela em modelo canino / The influence of para-areolar incision in the upper outer quadrant of the breast, the location of the sentinel lymph node in canine model

CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / Este trabalho aborda a influÃncia da incisÃo para-areolar no quadrante superior externo da mama, na localizaÃÃo do linfonodo sentinela em modelo canino. A BiÃpsia do linfonodo sentinela (BLS) à um mÃtodo de amostragem seletiva, minimamente invasivo, altamente sensÃvel em predizer o estado axilar, podendo evitar o esvaziamento ganglionar em pacientes sem comprometimento metastÃtico. Mulheres, com cirurgias mamÃrias previas, foram excluÃdas da realizaÃÃo da BLS por muitos cirurgiÃes por acreditar que teriam um Ãndice de falso negativo elevado, inviabilizando o mÃtodo. Outros mastologistas passaram a empregar, empiricamente, a injeÃÃo do marcador corante ou radioativo acima da borda da incisÃo prÃvia, porÃm fica a dÃvida se o gÃnglio identificado à realmente o Linfonodo Sentinela (LS). Este trabalho experimental, em modelo canino, tem como objetivo identificar a influÃncia das incisÃes para-areolares prÃvias, no quadrante superior externo (QSE) da mama na identificaÃÃo do linfonodo sentinela. à utilizado o radiocolÃide TecnÃcio99 injetado na derme sub-areolar das mamas torÃcicas craniais, para marcar o LS. Esperado o tempo de migraÃÃo do radiofÃrmaco para axila e identificado o local de marcaÃÃo com probe. Procede-se incisÃo arciforme para- areolar no QSE, entre 9 e 12h à direita e 12 e 3 h à esquerda, a 2cm do mamilo. O corante azul patente Ã, entÃo, injetado na borda superior destas incisÃes. No ponto marcado com o gama-probe à realizada a incisÃo axilar mÃnima, onde o LS à identificado com auxÃlio do probe, que capta a radiaÃÃo do gÃnglio, eou pela visualizaÃÃo direta do linfonodo impregnado com o corante. SÃo comparadas duas tÃcnicas de local de injeÃÃo e a concordÃncia entre os mÃtodos de identificaÃÃo do LS. Os experimentos da pesquisa ocorreram entre Janeiro 2008 e Maio 2009. A amostra à composta de 40 mamas torÃcicas craniais, oriundas de 23 cadelas adultas, sem raÃa definida, da espÃcie Canis familiaris. A anÃlise estatÃstica foi realizada com o auxÃlio do programa Graphpad e utilizados o Teste de McNemar e Coeficiente de ConcordÃncia de Kappa. Os resultados demonstram que em 95% das mamas estudadas (3840) obtiveram o LS identificado na axila apÃs a injeÃÃo de tecnÃcio na regiÃo subareolar e em 82% dos casos (33/40) coraram com azul patente injetado no bordo superior da incisÃo padronizada. Os resultados obtidos indicam a concordÃncia entre os mÃtodos em 82% dos casos na identificaÃÃo do LS (3340). As incisÃes para-areolares prÃvias, nos quadrantes superiores externos, das mamas torÃcicas craniais da cadela, nÃo demonstram interferir, de maneira significante, na BLS quando o corante à injetado na borda superior da incisÃo. O linfonodo encontrado a partir de injeÃÃo na borda superior da incisÃo previa, corresponde ao linfonodo sentinela da mama da cadela, em 95% dos casos (3233). / This paper discusses the influence of para-areolar incision in the upper outer quadrant of the breast for the location of the sentinel lymph node in canine model. Sentinel lymph node biopsy (SLNB)―a minimally invasive selective sampling technique highly predictive of the condition of the armpit―can spare metastasis-free patients from unnecessary axillary dissection. The high incidence of false-negative results has led many surgeons to no longer indicate SLNB to women with previous breast surgery. Some mastologists prefer to empirically inject a dye or radio-labelled marker above the border of the previous incision, though it is not always clear if the identified ganglion is in fact the sentinel lymph node. The objective of the present study was to evaluate the influence of previous para-areolar incisions in the upper outer quadrant (UOQ) of the breast upon the identification of the sentinel lymph node (SLN) in a canine model. The SLN was marked with Technetium-99m (99mTc) injected into the subareolar skin of the cranial breast. Once the marker had migrated to the axilla and the marked site had been identified with a gamma probe, an arcuate para-areolar incision was performed 2 cm from the nipple in the UOQ (between the 9 and 12 oâclock position on the right side, and between the 12 and 3 oâclock position on the left side). Patent blue dye was then injected above the upper border of the incision. At the marked site a minimal axillary incision was made and the SLN was identified by gamma probe and/or by direct visualization of the dye. The agreement between the two injection sites and the two SLN identification methods was determined. The experiments were carried out between January 2008 and May 2009 on a sample of 40 cranial breasts of 23 adult females of the species Canis familiaris. Using the statistics software Graphpad, the data were submitted to the McNemar test and the Kappa agreement coefficient was calculated. Our findings show that in 95% (38/40) of the breasts the SLN was identified by injection of 99mTc in the subareolar region, and that in 82% (33/40) of cases the SLN was identified by injection of patent blue dye above the upper border of the incision. Thus, the methods agreed in 82% (33/40) of cases. Previous para-areolar incisions in the UOQ of the cranial breasts did not interfere significantly with the biopsy when the dye was injected above the upper border of the incision. The lymph node identified by injection above the upper border of the previous incision corresponded to the SLN in 95% (32/33) of cases.

Identiferoai:union.ndltd.org:IBICT/oai:www.teses.ufc.br:3645
Date26 February 2010
CreatorsPaulo Henrique Diogenes Vasques
ContributorsLuiz Gonzaga Porto Pinheiro, Renato Santos de Oliveira Filho, Lusmar Veras Rodrigues
PublisherUniversidade Federal do CearÃ, Programa de PÃs-GraduaÃÃo em Cirurgia, UFC, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Formatapplication/pdf
Sourcereponame:Biblioteca Digital de Teses e Dissertações da UFC, instname:Universidade Federal do Ceará, instacron:UFC
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0033 seconds