5 Abstract This Diploma Thesis is targeted on the determination of 5-nitrobenzimidazole (5-NBIA) using following techniques: DC voltammetry (DCV) and differential pulse voltammetry (DPV). As working electrodes, a silver amalgam paste electrode (AgA-PE), which was constructed for this determination in the form of a new prototype, a bismuth film electrode (BiFE), at which the optimum conditions for the deposition of the bismuth film at a suitable substrate (glassy carbon electrode and gold electrode were tested for this purpose) were initially optimized, and a glassy carbon electrode (GCE) were used. The optimum conditions for the voltammetric determination of 5-NBIA at the AgA-PE (in a medium of Britton-Robinson buffer (BR-buffer) of pH 7.0 for both DCV and DPV), at the BiFE with gold substrate (BR-buffer of pH 9.0 for both DCV and DPV; the film was deposited "ex situ" in a stirred plating solution (1000 mg L-1 Bi(III) solution in 0.1 mol L-1 acetate buffer of pH 4.5) for 300 s), and at the GCE (BR-buffer of pH 5,0 for both DCV and DPV). Under these conditions, calibration dependences were measured in the concentration ranges of 0.1 - 100 µmol L-1 (pro DCV a DPV na AgA-PE) and 1 - 100 µmol L-1 (pro DCV a DPV na BiFE a GCE), and the limits of quantification (LQs) were calculated for particular methods: LQ ≈...
Identifer | oai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:307436 |
Date | January 2012 |
Creators | Chládková, Barbora |
Contributors | Vyskočil, Vlastimil, Zima, Jiří |
Source Sets | Czech ETDs |
Language | Czech |
Detected Language | English |
Type | info:eu-repo/semantics/masterThesis |
Rights | info:eu-repo/semantics/restrictedAccess |
Page generated in 0.002 seconds