Desenvolvimento de um dispositivo auxiliar para calibração de bombas de roletes utilizadas em circulação extracorpórea / Development of an auxiliary device for calibration of roller pumps used in extracorporeal circulation

Orientadores: Eduardo Tavares Costa, Francisco Ubaldo Vieira Júnior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-19T00:09:22Z (GMT). No. of bitstreams: 1
MedeirosJunior_JohannesDantasde_M.pdf: 2215491 bytes, checksum: e35d132e2a61efa2d559a4dba08e356e (MD5)
Previous issue date: 2011 / Resumo: Circulação extracorpórea é um processo no qual o sangue circula externamente ao corpo com o intuito de manter a oxigenação e o fluxo do sangue adequados durante a realização de determinados procedimentos cirúrgicos; para realizá-la é utilizado um conjunto de técnicas e equipamentos cuja função é substituir temporariamente o coração e os pulmões. Contudo, a circulação extracorpórea é percebida pelo organismo como um agente agressor e um dos principais parâmetros relacionados aos danos que ela provoca é a hemólise. O uso de bombas propulsoras é um dos causadores de hemólise em procedimentos envolvendo circulação extracorpórea e um dos principais tipos de bombas propulsoras é a bomba de roletes. A hemólise provocada pelo uso de bomba de roletes é devida principalmente ao grau de oclusão utilizado. Há dois métodos geralmente utilizados para calibração da bomba de roletes: o método de velocidade de queda e o método de calibração dinâmica. Nesse trabalho é proposto um dispositivo para auxiliar o perfusionista a ajustar bombas de roletes por um método menos oclusivo, a calibração dinâmica. O dispositivo é baseado em um microcontrolador PIC 18F4523 e é utilizado em conjunto com transdutores de pressão descartáveis normalmente utilizados em procedimentos cirúrgicos. Foram determinadas as curvas características de três transdutores de pressão na faixa de 0 a 1000 mmHg. Os resultados das calibrações realizadas com o protótipo desenvolvido foram comparados com os resultados obtidos com uma placa de aquisição de dados comercial. Dois, dos três transdutores, foram submetidos a testes de fadiga e um foi mantido como referência. Para validação do dispositivo, sendo utilizado para realizar calibração dinâmica, foram testados ajustes em 150, 250, 350, 450 e 500 mmHg. Em cada ajuste foram realizadas 8 medições simultâneas de pressão média de calibração dinâmica com o dispositivo e com uma placa de aquisição de dados comercial. Após a realização de todos os testes, os transdutores foram novamente caracterizados. As curvas características dos três transdutores obtidas na caracterização inicial mostraram igualdade estatística (p > 0,05). Após os testes de fadiga não foram observadas alterações nas respostas dos transdutores de pressão no início e após a realização dos testes, nos mesmos pontos de pressão (p > 0,05). As medidas de pressão de calibração dinâmica realizadas com o protótipo apresentaram igualdade estatística (p > 0,05) para toda a faixa de pressão testada, quando comparados com os respectivos resultados obtidos com a placa de aquisição de dados. Conclui-se que os transdutores utilizados atualmente em procedimentos cirúrgicos podem ser utilizados na calibração dinâmica sem perdas de características e que o dispositivo construído pode ser utilizado em ambiente operatório para ajustes de bombas de roletes pelo método de calibração dinâmica / Abstract: Cardiopulmonary bypass is a procedure in which blood circulates outside the body in order to maintain oxygenation and blood flow conditions during the performance of certain surgical procedures; for this procedure, it is used a set of equipments whose function is to temporarily replace the heart and lungs. However, the cardiopulmonary bypass is perceived by the body as an aggressor agent and one of the main parameters related to the damage it causes is hemolysis. The use of driving pumps is a cause of hemolysis in procedures involving cardiopulmonary bypass and one of the main types of driving pumps is the roller pump. Hemolysis caused by the use of roller pump is mainly due to the degree of roller occlusion used. There are two methods commonly used for adjusting the roller pump: the method of drop rate and the dynamic calibration method. In this work, we developed a device to assist the perfusionist adjust roller pumps by a less occlusive method, the dynamic calibration method. The device is based on a PIC 18F4523 microcontroller and is used in conjunction with disposable pressure transducers commonly used in surgical procedures. We have characterized three pressure transducers in the range of 0 to 1000 mmHg. Calibration results obtained with the prototype were compared with those obtained with a data acquisition board. Two of the three transducers were submitted to fatigue tests and one was kept as a reference. To validate the constructed device, being used to perform dynamic calibration, adjustments were at 150, 250, 350, 450 and 500 mmHg, in each set were performed eight simultaneous measurements of dynamic calibration mean pressure with the device and with a data acquisition board. After all tests were conducted, the transducers were re-characterized. The three characteristic curves obtained in the initial characterization showed statistically equivalence (p > 0.05) among themselves. After the fatigue tests no changes were observed in the responses of pressure transducers in the beginning and in the end of the tests, at the same pressure points (p > 0.05). Measurements of dynamic calibration pressure obtained with the prototype showed statistically equivalence (p > 0.05) throughout the tested pressure range, when compared with the results obtained with the data acquisition board. We conclude that the transducers currently used in surgical procedures may be used for dynamic calibration without losing their characteristics and that the constructed device can be used in surgery to adjust the roller pumps by the dynamic calibration method / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/321693
Date29 June 2016
CreatorsMedeiros Júnior, Johannes Dantas de
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Vieira Junior, Francisco Ubaldo, Costa, Eduardo Tavares, 1956-, Fiorelli, Alfredo Inácio, Oliveira, Pedro Xavier de
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Elétrica e de Computação, Programa de Pós-Graduação em Engenharia Elétrica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format87 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0028 seconds