This master’s thesis describes the design and calculation of the biomass hot water boiler which should be used for heating of office buildings in a collective farm. Fuel composition was determined by recommended literature. Stoichiometric calculations were processed for the fuel composition. The required boiler heat output was determined and compared with the original gas boiler, which was previously used for heating. The thermal calculation of the boiler and the design of the heat exchanger was also performed.