Return to search

Caldeiras aquatubulares de bagaço : estudo do sistema de recuperação de energia / Aquatubular boilers fueled by bagasse : study of energy recovery system

Orientador: Silvia Azucena Nebra de Perez / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-12T18:40:07Z (GMT). No. of bitstreams: 1
SosaArnao_JuanHarold_D.pdf: 4617781 bytes, checksum: 0d60bc60f546a91e312ce66083a35ec5 (MD5)
Previous issue date: 2007 / Resumo: SOSA ARNAO, Juan Harold, Caldeiras Aquatubulares de Bagaço - Estudo do Sistema de Recuperação de Energia, Campinas, Faculdade de Engenharia Mecânica, Universidade Estadual de Campinas, 2008. 224p. O objetivo deste trabalho foi avaliar o desempenho termodinâmico da caldeira de bagaço e reduzir o custo do seu sistema de recuperação de energia dos gases de exaustão. Para isso, foi realizada a caracterização do bagaço; após o que se determinou a velocidade terminal e o coeficiente de arrasto. Também, propriedades do bagaço como: o poder calorífico superior, a exergia, a temperatura de início de pico ou step, e a temperatura de auto-ignição foram determinadas. O desempenho da caldeira foi determinado através da aplicação da Primeira e Segunda Leis da Termodinâmica. Na análise de Primeira Lei, a eficiência da caldeira foi determinada através do método: (i) das Entradas e Saídas e (ii) do Balanço de Energia, ambos calculados na base do poder calorífico inferior (PCI) e superior (PCS). Na análise de segunda lei, o método dos insumos e produtos e do balanço de exergia foram aplicados. Uma metodologia do balanço de exergia, específica para caldeiras de combustível úmido, foi desenvolvida e aplicada neste trabalho. Através destas análises, o desempenho de quatro sistemas de geração de vapor foi estudado. Estes sistemas foram compostos por: (i) gerador de vapor, economizador de alta temperatura, pré-aquecedor de ar e economizador de baixa temperatura; (ii) gerador de vapor, pré-aquecedor de ar e economizador; (iii) gerador de vapor, pré-aquecedor de ar e secador de bagaço e (iv) gerador de vapor, economizador, pré-aquecedor de ar e secador de bagaço. Os resultados mostraram que o efeito da umidade do bagaço é o fator mais importante no desempenho da caldeira, o qual pode ser melhorado com a inserção de secadores. Além disso, o sistema de geração de vapor, composto pelo: gerador de vapor, economizador, pré-aquecedor de ar e secador de bagaço apresentou o melhor desempenho termodinâmico e também, o menor custo do sistema de recuperação de energia dos gases de exaustão. / Abstract SOSA ARNAO, Juan Harold, Aquatubular boilers fueled by bagasse - Study of Energy Recovery System, Campinas, Faculdade de Engenharia Mecânica, Universidade Estadual de Campinas, 2008. 224 p. The objective of this work was to evaluate the bagasse boiler thermodynamic performance and reduce the cost of its waste gases energy recovery system. For that, the bagasse characterization was realized; from which, the free-settling velocity and drag coefficient were determined. Also, the bagasse properties, such as, the higher heating value, the exergy, the step or peak initial temperature and ignition spontaneous temperature were determined. The bagasse boiler performance was determined through the application of Thermodynamic First and Second Law. In the first law analysis, the boiler efficiency was determined through (i) Input/Output and (ii) Energy Balance Method, which were calculated based on higher heating value (HHV) and lower heating value (LHV). In the second law analysis, the product/fuel and exergy balance methods were applied. A methodology of exergy balance, specific for wet fuels, was developed and applied in this work. Through these analyses the performance of four steam generation systems was studied. These systems were composed by: (i) steam generator, high temperature economizer, air heater and low temperature economizer; (ii) steam generator, air heater and economizer; (iii) steam generator, air heater and bagasse dryer and (iv) steam generator, economizer, air heater and bagasse dryer. The results showed that the bagasse moisture content effect is the most important factor in boiler performance, which can be improved with the inclusion of bagasse dryers. Besides, the steam generation system composed by: steam generator, economizer, air heater and bagasse dryer presented the best thermodynamic performance and also the lowest cost of the waste gases energy recovery system. Key Words Boiler, bagasse, economizer, air heater, dryer, exergy. / Doutorado / Termica e Fluidos / Doutor em Engenharia Mecânica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/265071
Date12 August 2018
CreatorsSosa Arnao, Juan Harold
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Nebra, Silvia Azucena, 1943-, Perez, Silvia Azucena Nebra de, Junior, Leonardo Goldstein, Silveira, Jose Luz, Bizzo, Waldir Antônio, Bazzo, Edson
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Mecânica, Programa de Pós-Graduação em Engenharia Mecânica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format233 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0034 seconds