Return to search

Cálculo dos parâmetros dosimétricos de sementes de braquiterapia de 125I para implantes permanentes em próstata atraves do método de Monte Carlo / Monte Carlo calculation of dosimetric parameters of 125I brachytherapy seeds used in permanent prostate implants

No tratamento do câncer de próstata, há um crescente interesse na técnica do implante permanente de sementes, na qual as sementes radioativas são inseridas na próstata do paciente permitindo a entrega de doses elevadas e preservação dos órgãos de risco vizinhos. Estas sementes são normalmente feitas utilizando-se um de três radioisótopos: 125I, 103Pd e 131Cs. Devido à disponibilidade e por razões clínicas, as mais utilizadas são as sementes de iodo e, nos últimos anos, sementes com geometria interna e materiais diferentes estão sendo estudadas, a fim de melhorar suas características dosimétricas. Atualmente, no Brasil, implantes permanentes com sementes de 125I são realizados por algumas instituições médicas, principalmente por instituições privadas. As sementes são importadas com preços elevados, o que dificulta seu uso em hospitais públicos. Portanto, a fim de reduzir o custo financeiro dessa modalidade de tratamento e para melhorar as características dosimétricas das sementes existentes, é de grande importância ter uma tecnologia nacional. Uma matriz cerâmica que pode ser usada como portadora dos radioisótopos e marcadora radiográfica foi desenvolvida no Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN). Essa matriz cerâmica se distingue por sua capacidade de ter o material radioativo uniformemente distribuído, além de ser capaz de incorporar outros radioisótopos além do 125I. Neste trabalho foram calculadas as distribuições de dose de modelos de semente de 125I com matriz cerâmica e diferentes encapsulamentos (modelos em desenvolvimento no CDTN). As distribuições de dose foram calculadas conforme o protocolo TG-43U1 da Associação Americana de Físicos Médicos. As características dosimétricas dos modelos de semente do CDTN, demonstradas neste estudo, indicam que seu uso é viável. Elas possuem como principal característica uma maior e mais isotrópica deposição de dose próximo às extremidades da fonte. Suas características sugerem que um número menor de sementes seria necessário para alcançar um determinado valor de dose no volume a ser tratado ou então que iodo de menor atividade radioativa possa ser utilizado. Em ambos os casos, o custo do tratamento poderia ser reduzido. / In the prostate cancer treatment, there is an increasing interest in the permanent radioactive seeds implant technique, where radioactive seeds are inserted into the patients prostate, allowing the delivery of high doses and preserving nearby organs at risk. These seeds are usually made using 1 of 3 radioisotopes: 125I, 103Pd and 131Cs. Due to availability and clinical reasons, the most used are the iodine seeds and, in recent years, seeds with different internal geometry and materials are being studied, in order to improve the dosimetric characteristics of the sources. Currently, in Brazil, permanent implants with 125I seeds are performed by a few medical institutions, mostly private ones. The seeds are imported with high prices, which prohibits their use in public hospitals. Therefore, in order to reduce the financial cost of this treatment modality and to improve the dosimetric characteristics of the existing seeds, it is of great importance to have a national technology. A ceramic matrix that can be used as a radioisotope carrier and radiographic marker was developed at CDTN/CNEN. The ceramic matrix is distinguished by its ability to have the radioactive material evenly distributed besides being able to incorporate radioisotopes other than 125I. In this work we calculate the dose distribution of 125I seed models with ceramic matrix and different encapsulation (CDTNs seed models under development). The dose distributions were calculated according to the TG-43U1 protocol of the American Association of Physicists in Medicine. The dosimetric characteristics of the CDTNs seed models, demonstrated in this study, indicate that their use is feasible. They have as main feature a larger and more isotropic dose deposition near the ends of the source. Their characteristics suggest that a smaller number of seeds would be needed to achieve a particular dose value at the volume to be treated or that iodine with lower activity may be used. In both cases, the cost of treatment would be reduced.

Identiferoai:union.ndltd.org:IBICT/oai:bdtd.cdtn.br:109
Date04 February 2011
CreatorsLucas Paixão Reis
ContributorsSuely Epsztein Grynberg, Alexandre Soares Leal, Alessandro Facure Neves de Salles Soares, Helio Yoriyaz
PublisherCNEN - Centro de Desenvolvimento da Tecnologia Nuclear, Belo Horizonte, CTRA - Programa de Pós-Graduação em Ciência e Tecnologia das Radiações, Minerais e Materiais, CDTN, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Formatapplication/pdf
Sourcereponame:Biblioteca Digital de Teses e Dissertações do CDTN, instname:Centro de Desenvolvimento da Tecnologia Nuclear, instacron:CDTN
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.002 seconds