The Astoria-Megler Bridge is a 6.6 kilometer (4.1 mile) long bridge, connecting Oregon and Washington on US 101, with a continuous steel truss main span of 376 m (1232 ft). It is the second longest main span bridge of this type in the world. Due to vortex shedding, some of the long truss verticals exhibit wind-induced torsional vibrations. These vibrations can create large numbers of repeated stress cycles in the truss verticals and the gusset plate assemblies. The members and connections were not designed for such conditions and the impact of this behavior on the service life of the bridge is uncertain.
A full-scale representation of one of the truss verticals observed to exhibit such wind induced torsional response was fabricated and tested in the Structural Engineering Research Laboratory at Oregon State University. Experimental data of the rotational behavior and the stress distribution along the vertical were collected using inclinometers, an angular rate sensor, and uniaxial and rosette strain gages. The data collected were compared with existing analytical methods and predictions from finite element models. The observed experimental results including twist angle, stress distribution, and stress magnitude were well captured by both the finite element model and the analytical equations. Using analytical expressions, the fatigue lives of the existing bridge verticals were predicted based on assumed storm duration and recurrence. / Graduation date: 2013
Identifer | oai:union.ndltd.org:ORGSU/oai:ir.library.oregonstate.edu:1957/30345 |
Date | 13 June 2012 |
Creators | Keller, Philipp |
Contributors | Higgins, Christopher C. |
Source Sets | Oregon State University |
Language | en_US |
Detected Language | English |
Type | Thesis/Dissertation |
Page generated in 0.0026 seconds