Orientador : Francisco Haiter Neto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-31T15:16:05Z (GMT). No. of bitstreams: 1
Ganzerli_AnnaSilviadaRocha_M.pdf: 3290878 bytes, checksum: 1c235f5f50b017f665a33c399fda8621 (MD5)
Previous issue date: 2001 / Resumo: O objetivo dessa pesquisa foi comparar dois sistemas digitais de armazenamento de fósforo e filme radiográfico convencional e também verificar a concordância interexaminadores no diagnóstico radiográfico de cáries oclusais e proximais. Utilizou-se dois sistemas digitais e filme radiográfico convencional para avaliar 144 superfícies dentárias com e sem cáries, numa escala de confiança de 4 pontos. Participaram como examinadores 13 alunos de graduação e um radiologista. Para a confirmação da presença ou não de cáries foi realizada a microscopia óptica da amostra. A análise dos resultados mostrou não haver diferença significante entre os sistemas radiográficos, entretanto todos tiveram diferenças significantes quando comparados à microscopia óptica, com exceção ao sistema Digora, nas superfícies proximais quando o radiologista foi o examinador. Na avaliação interexaminadores (alunos), obteve-se um nível regular de concordância e entre os alunos e o radiologista obteve-se nível sofrível a regular. Com relação a validade (sensibilidade, especificidade, preditivos positivos e preditivos negativos), os valores foram semelhantes entre os alunos e o radiologista, com exceção dos valores de sensibilidade nas superfícies oclusais. Um maior número de resultados falsos-negativo foi encontrado nas avaliações feitas pelos alunos, enquanto o radiologista proporcionou maior número de resultados falsos-positivos / Abstract: The purpose of this research was to compare two digital storage phosphor systems and conventional film, as well as verify the agreement interexaminers in radiographic diagnosis on occlusal and proximal cavities. Two digital systems and conventional radiographic film were used to evaluate 144 tooth surfaces with and without cavities; the radiographs were analyzed and scored in a scale of 4 points. Thirteen ungraduated students and an oral radiologist participated as examiners. It was accomplished an optical microscopy analysis in order to validate the research. The results showed that there wasn't significant difference among the radiographic systems, however, ali of them had significant differences when they were compared to the optical microscopy, except the Digora system, in the proximal su rface , when the radiologist was the examiner. In the interexaminers evaluation, it was obtained a moderate agreement levei and among the students and the oral radiologist it was obtained a fair to moderate leveI. Regarding to the validation (sensibility, specificity, positive predict and negative predict) the values were similar among the students and the oral radiologist, except the sensibility value in occlusal surface. The students had the highest number of false-positive results and the oral radiologist the highest number of false-negative results / Mestrado / Mestre em Radiologia Odontológica
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288996 |
Date | 26 April 2001 |
Creators | Ganzerli, Anna Silvia da Rocha |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Haiter Neto, Francisco, 1964-, Tosoni, Guilherme M., Almeida, Solange Maria de |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Radiologia Odontológica |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 142p. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0022 seconds