The work is a project of a component that allows lift transform rollers skewing. Three possible ways of construction are introduced. Their advantages and disadvanatages are mentioned. The best option was selected and checked by FEM. Prestressed bolted connection was also worked out. In the conclusion of the paper there is a source code of the computer programme for maximum rollers skew calculation.
Identifer | oai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:228019 |
Date | January 2008 |
Creators | Žák, Martin |
Contributors | Chalupský, Petr, Špička, Jiří |
Publisher | Vysoké učení technické v Brně. Fakulta strojního inženýrství |
Source Sets | Czech ETDs |
Language | Czech |
Detected Language | English |
Type | info:eu-repo/semantics/masterThesis |
Rights | info:eu-repo/semantics/restrictedAccess |
Page generated in 0.0022 seconds