Orientador: Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-26T13:35:05Z (GMT). No. of bitstreams: 1
Fugolin_AnaPaulaPiovezan_D.pdf: 4905643 bytes, checksum: 75a91fcf559fc00359be8feeeb2d2a0c (MD5)
Previous issue date: 2015 / Resumo: Novos compósitos bulk-fill, autoadesivos e de menor contração foram desenvolvidos propondo mudanças na técnica restauradora incremental preconizada. Os objetivos desta pesquisa foram: 1) analisar os compósitos Tetric EvoCeram Bulk Fill (TEC), Surefil SDR (SDR), Vertise Flow (VF), Filtek Low Shrinkage (SIL) e compará-los com o compósito convencional Z100 (Z100) quanto à contração volumétrica, tensão de contração, grau de conversão, cinética, resistência à flexão e módulo de elasticidade; 2) avaliar a profundidade de polimerização e a resistência da união à tração de cavidades de Classe II restauradas com diferentes técnicas e diversas associações de materiais submetidas à ciclagem mecânica; e 3) analisar a adaptação marginal por microscopia eletrônica de varredura de restaurações de Classe II antes e após ciclagem mecânica e resistência coesiva. No capitulo 1, a contração volumétrica foi avaliada por dilatômetro de mercúrio e bonded disc (n=5) e a tensão de contração com Bioman (n=5). O grau de conversão foi analisado com espectroscopia de infravermelho próximo (NIR) (n=5) e a cinética por meio de optical bench (n=5). Resistência à flexão e módulo de elasticidade foram mensurados em ensaio com três pontos de apoio após 10 e 60 minutos da fotoativação. Os dados foram analisados por ANOVA e teste de Tukey (5%). VF apresentou os maiores valores de contração volumétrica e tensão de contração, enquanto que SIL obteve os menores. SDR apresentou a maior taxa de polimerização e os maiores valores de grau de conversão. VF apresentou os maiores valores de resistência à flexão após 10 e 60 minutos e Z100 os maiores valores de módulo de elasticidade. No capítulo 2, cavidades de Classe II ocluso-distais em terceiros molares humanos extraídos foram restauradas usando sistema adesivo convencional ¿ XP Bond (XP) ou à base de silorano (SSA) associado aos compósitos TEC, SDR, VF, SIL e Z100 inseridos por meio da técnica incremental (I) e bulk (B). Os grupos experimentais testados foram: XP-Z-B, XP-Z-I, SSA-Z-B, SSA-Z-I, XP-TEC-B, XP-TEC-I, XP-SDR-Z100, SSA-SDR-Z100, VF-Z-B e SSA-SIL-B (n=8). Metade do total das amostras foi preparada para obtenção de palitos e submetida ao teste de resistência da união à microtração após sete dias de armazenagem, enquanto outra metade foi submetida à ciclagem mecânica antes do ensaio de resistência da união. A profundidade de polimerização foi mensurada em restaurações com 4,0 mm de profundidade removidas da cavidade e submetidas ao ensaio de dureza Knoop (n=3). Os resultados foram analisados por ANOVA e teste de Tukey (5%). Quanto à resistência de união o grupo XP-SDR-Z apresentou os maiores valores em ambas as superfícies (oclusal e cervical) nos grupos ciclados ou não. Os menores valores foram exibidos por VF-Z-B em ambas as superfícies para os grupos não ciclados e SSA-SDR-Z para os ciclados. Em relação à profundidade de polimerização, VF apresentou a maior redução da dureza, enquanto os demais compósitos apresentaram valores de redução menores do que 20%. No capítulo 3, as cavidades de Classe II restauradas seguiram as mesmas etapas dos grupos experimentais apresentados no capítulo 2 (n=5) e foram submetidas ao ensaio de ciclagem mecânica; porém, foram previamente moldadas para obtenção de replicas para análise da integridade marginal em microscopia eletrônica de varredura. As imagens foram analisadas pelo software Image J para verificar a porcentagem de fendas. Os compósitos utilizados para restaurar as cavidades foram submetidos ao teste de resistência coesiva (n=5). Os resultados foram analisados por ANOVA e teste de Tukey (5%). A análise da adaptação marginal qualitativa e quantitativa mostrou alteração significativa antes e após a ciclagem mecânica apenas para todos o grupo SSA-Z-B. Os resultados de resistência coesiva mostraram que Z100, SDR e SIL apresentaram os maiores valores, seguido de TEC. VF apresentou os menores valores. Concluiu-se que os novos compósitos apresentam propriedades comparáveis e, em algumas situações, melhores quando comparado ao compósito convencional / Abstract: New bulk-fill, self-adhering and low shrinkage materials were developed and purposed significant changes in the preconized incremental restorative technique. The aims of this research were: 1) analyze the new composites represented by Tetric EvoCeram Bulk Fill (TEC), Surefil (SDR), Vertise Flow (VF), Filtek Low Shrinkage (SIL) and compare them with the conventional composite Z100 (Z100) in relation to volumetric shrinkage, stress of polymerization, degree of conversion, kinetics, flexural strength and modulus; 2) evaluate depth of cure of different composites and microtensile bond strength of Class II cavities filled by different restorative techniques and materials association submitted to mechanical fatigue-cycling test; and 3) analyze marginal adaptation by scanning electron microscopy (SEM) of Class II restoration before and after mechanical cycling, and ultimate tensile strength. In the charter 1, the volumetric shrinkage was evaluated by mercury dilatometer and bonded-disc techniques (n=5) and stress of polymerization by Bioman instrument (n=5). Degree of conversion was analyzed with NIR-spectroscopy (n=5) and the kinetics by the optical bench (n=5). Flexural strength and modulus were carried out using a three-point bending test after 10 and 60 minutes after photocuring. Results were analyzed by ANOVA and Tukey¿s test (5%). VF showed the highest values of volumetric shrinkage and stresses of polymerization and SIL the lowest ones. SDR obtained the highest rate of polymerization and the highest degree of conversion values. VF presented the highest values of flexural strength in both tested times, and Z100 the highest values of modulus. In the charter 2, Class II occluso-distal cavities (6 x 2 x 4 mm) in extracted human molars were restored using a etch-and-rinse adhesive system ¿ XP Bond (XP) or silorane-based (SSA) associated to TEC, SDR, VF, SIL and Z100 composites placed by incremental (I) or bulk (B) technique. The tested experimental groups were: XP-Z-B, XP-Z-I, SSA-Z-B, SSA-Z-I, XP-TEC-B, XP-TEC-I, XP-SDR-Z100, SSA-SDR-Z100, VF-Z-B e SSA-SIL-B (n=8). Half of the samples were prepared to obtain sticks and submitted to the microtensile bond strength test after 7 days of storage. The other samples were submitted to the mechanical fatigue-cycling test before the microtensile bond strength test. Depth of cure was carried out in restorations with 4.0 mm of depth, removed and submitted to Knoop hardness test (n=3). Results were statistically analyzed by ANOVA and Tukey¿s test (5%). In relation to microtensile bond strength, in overall, XP-SDR-Z showed the highest values in both analyzed surfaces (occlusal and cervical) in cycling and no-cycling groups. The lowest values were exhibited by VF-Z-B in both analyzed surfaces in no-cycling groups and SSA-SDR-Z in cycling groups. In relation to depth of cure, VF obtained the lowest top-to-bottom ratio, while the other tested composites exhibited less than 20% of reduction. In the charter 3, Class II cavities were prepared following the same steps described in charter 2 (n=5) and were carried out to mechanical fatigue-cycling test. However, impressions were made before and after to obtain replicas to SEM analysis of the marginal integrity. The micrographs were analyzed by Image J software to measure the discontinuity percentage. The composites used in the cavities were submitted to the ultimate tensile strength (UTS) (n=5). Results were statistically analyzed by ANOVA and Tukey¿s test (5%). Marginal adaptation analysis did not show significant alteration before and after cycling for all groups except to SSA-Z-B where cracks and gaps were found in the adhesive interface. In relation to UTS results Z100, SDR and SIL showed the highest results, followed by TEC. VF exhibited the lowest values. It is possible to conclude that new composites show comparable properties and in some situation better than conventional material / Doutorado / Materiais Dentarios / Doutora em Materiais Dentários
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/290053 |
Date | 26 August 2018 |
Creators | Fugolin, Ana Paula Piovezan, 1987- |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Consani, Simonides, 1939-, Brandt, William Cunha, Guiraldo, Ricardo Danil, Correr Sobrinho, Lourenço, Lima, Débora Alves Nunes Leite |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Materiais Dentários |
Source Sets | IBICT Brazilian ETDs |
Language | Multilíngua |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis |
Format | 72 f. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0029 seconds