Submitted by Fatima Fonseca (fatima.fonseca@sibi.ufrj.br) on 2017-12-15T16:27:49Z
No. of bitstreams: 1
159026.pdf: 4100389 bytes, checksum: 1c58fb35c20bda88cc115fda10a08a14 (MD5) / Made available in DSpace on 2017-12-15T16:27:49Z (GMT). No. of bitstreams: 1
159026.pdf: 4100389 bytes, checksum: 1c58fb35c20bda88cc115fda10a08a14 (MD5)
Previous issue date: 1983-02 / O presente trabalho se refere a parte do programa de pesquisas contratado à COPPE pela Companhia do Metrô do Rio de Janeiro, realizado junto com a construção das galerias subterrâneas do mesmo. Neste trabalho desenvolveu-se o estudo de dois tipos de instrumentos construídos pela COPPE para utilização
na observação das escavações, que são as Células de Carga e os Piezômetros Pneumáticos. As Células de Carga foram empregadas na avaliação dos esforços atuantes nas paredes diafragma, e resistidos pela estroncas, gerados pelo empuxo dos maciços arrimados, enquanto que os Piezômetros Pneumáticos foram utilizados para a quantificação das pressões neutras nos maciços adjacentes às paredes diafragma, bem como para avaliar pressões hidráulicas em fundos de cavas. O desenvolvimento do presente trabalho envolveu, para cada um dos equipamentos analisados, a pesquisa dos diversos tipos de aparelhos similares, a descrição dos aparelhos desenvolvidos pela COPPE incluindo considerações sobre os materiais
empregados em suas construções e processos de calibração, a análise do projeto executado e as conclusões e recomendações a respeito da qualidade e melhorias propostas a estes aparelhos. Além disto, em anexos são apresentados tópicos de construção, calibração e a base de realização deste trabalho que foram as sucessivas calibrações das Células de Carga e a instalação de teste dos Piezômetros Pneumáticos. / This text refers to a part of the research program contracted to COPPE by the Rio de Janeiro Subway Company, for the instrumentation of excavations. ln the text two instruments built by COPPE to be utilized in the field, are examined: Load Cells and Hidraulic Piezometers. The Load Cells were utilized in the strutted diaphragm wall to measure the loads that were carried by the struts, while the Pneumatic Piezometers were utilized measurement of the pore-water pressure behind the walls and at the bottom excavation. This work contains for each one of above instruments, a litterature review of similar equipments, and the description
of the COPPE developed instruments, including considerations about the quality of the construction materials, calibration process, final design analysis, conclusions and recomendations about the fitness of the instruments and proposed alterations. The appendix contains topics about construction and calibration of Load Cells and field tests of the Pneumatic Piezometers.
Identifer | oai:union.ndltd.org:IBICT/oai:pantheon.ufrj.br:11422/3322 |
Date | 02 1900 |
Creators | Fusaro, Fernando |
Contributors | Lopes, Francisco de Rezende, Mahler, Claudio Fernando, Sandroni, Sandro Salvador, Lacerda, Willy Alvarenga |
Publisher | Universidade Federal do Rio de Janeiro, Programa de Pós-Graduação em Engenharia Civil, UFRJ, Brasil, Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa em Engenharia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFRJ, instname:Universidade Federal do Rio de Janeiro, instacron:UFRJ |
Rights | info:eu-repo/semantics/openAccess |