Return to search

Desenvolvimento e aplicação de metodologia para avaliação de desempenho hidroenergético de sistemas de abastecimento de água / Development of methodology and implementing for assessing hydro-energetic performance in water supply systems

Submitted by Nathalya Silva (nathyjf033@gmail.com) on 2017-04-24T19:48:15Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Tese_DesenvolvimentoMetodologiaAvaliacao.pdf: 16688032 bytes, checksum: 8a6e2d511a2ce435deaf0be98e401872 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-04-25T21:21:46Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Tese_DesenvolvimentoMetodologiaAvaliacao.pdf: 16688032 bytes, checksum: 8a6e2d511a2ce435deaf0be98e401872 (MD5) / Made available in DSpace on 2017-04-25T21:21:46Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Tese_DesenvolvimentoMetodologiaAvaliacao.pdf: 16688032 bytes, checksum: 8a6e2d511a2ce435deaf0be98e401872 (MD5)
Previous issue date: 2016-02-19 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A Tese de Doutorado teve por objetivo o desenvolvimento de metodologia e sua
implementação em software para avaliação de desempenho hidroenergético de sistemas
de abastecimento de água (SAA), bem como aplicação em sistema de escala real. A
pesquisa foi executada em duas etapas: 1) foi modelado todo o processo de avaliação de
desempenho hidroenergético, foram estabelecidas formulações para cálculo de perdas
hidroenergéticas e implementada metodologia em software; 2) foi realizada a aplicação
da metodologia em SAA de escala real, que necessitou de monitoramento de grandezas
hidroenergéticas e de simulação computacional do mesmo SAA no Epanet 2.0. Os
resultados da primeira etapa consistiram na definição de perdas hidroenergéticas, na
conceituação de desempenho hidroenergético, na metodologia proposta
(sequenciamento de ações e inerentes formulações matemáticas) para o cálculo de
perdas hidroenergéticas e para avaliação de desempenho hidroenergético de SAA, na
implementação da metodologia em software (batizado de SADHE2A) e no teste da
metodologia com sucesso em SAA com dados sintéticos. Os resultados da segunda
etapa foram consequência da aplicação da metodologia, com uso do SADHE2A – versão
Beta, no SAA Guanabara (localizado na cidade de Ananindeua, Pará, Brasil), na qual
foram verificadas perdas globais de água de 55,42%/m e perdas globais de energia
elétrica consumida de 58,31% (ambos os desempenhos classificados como “ruim”) que
ocasionaram impacto financeiro de -17.981,77 R$/mês (57,61% de toda a despesa com
consumo de energia elétrica no SAA, desde a captação de água bruta até a entrega de
água tratada ao consumidor). Por fim, a metodologia desenvolvida atendeu as
expectativas da pesquisa para calcular as perdas de água e de energia elétrica consumida
e avaliar o desempenho hidroenergético de SAA, com elevada potencialidade de uso no
Brasil e no exterior. / This doctoral thesis aims developing a methodology and implementing it on software in
order to evaluate a water supply system (WSS) hydro-energetic performance, as well as
applying it on a real scale WSS. This paper was carried out in two stages: 1) modeling
the hydro-energetic performance evaluation process, establishing of formulations to
calculate hydro-energetic losses and implementing methodology on software; 2)
applying the methodology at a real scale WSS, which required monitoring of hydraulic
and electrical quantities and simulating this WSS at Epanet 2.0. The first stage results
consisted at defined hydro-energetic losses and conceptualize hydro-energetic
performance on the proposed methodology, which consists sequences of actions and
mathematical formulation to calculate hydro-energetic losses at the WSS, as well as to
evaluate WSS hydro-energetic performance and, finally, at methodology
implementation in a software using Visual Basic for Applications (named as SADHE2A)
and successfully tested at the WSS with synthetic data. The second stage results are
related to methodology application at WSS of Guanabara (located at Ananindeua city,
Pará, Brazil), using SADHE2A – versão Beta, in which were identified water global
losses of 55.42% and electrical energy global losses of 58.31% (both classified as “bad”
by the methodology), resulting in an economical deficit of 17,981.77 R$/month. This
value is equivalent to 57.61% of electrical energy costs, since raw water pumping to the
final water costumer. Finally, the methodology developed has met the research
expectations to calculate the water losses and electricity consumed losses and to
evaluate the hydro-energetic performance of the WSS in Brazil and world.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/8245
Date19 February 2016
CreatorsREGO, Augusto da Gama
ContributorsPEREIRA, José Almir Rodrigues
PublisherUniversidade Federal do Pará, Programa de Pós-Graduação em Engenharia de Recursos Naturais da Amazônia, UFPA, Brasil, Instituto de Tecnologia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Sourcereponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0031 seconds