Return to search

Influencia de tempos alternativos de dessensibilização das placas de fosforo do sistema denoptix na qualidade da imagem digital / Performance of alternative DenOptix PSPs erasing times on subjective digital image quality

Orientador: Guilherme Monteiro Tosoni / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T15:57:15Z (GMT). No. of bitstreams: 1
Melo_DanielaPitade_M.pdf: 2421264 bytes, checksum: 450ce050ad326e2d47d3b89064367748 (MD5)
Previous issue date: 2007 / Resumo: O objetivo, neste trabalho, foi verificar se tempos alternativos de dessensibilização das placas de fósforo do sistema DenOptix causam interferência na qualidade da imagem radiográfica e no diagnóstico de cáries proximais. Foram obtidas imagens de 10 phantoms, constituídos de dentes humanos, utilizando-se placas de fósforo parcialmente dessenbilizadas. Os dez tempos de dessensibilização estudados foram em ordem decrescente: 130s, 98s, 66s, 34s, 25s, 20s, 15s, 10s, 5s e 0s. As imagens foram posteriormente avaliadas, quanto à sua qualidade subjetiva, por dois examinadores. Cada avaliador atribuiu escores para contraste, densidade e nitidez da imagem; para definição das estruturas - esmalte, dentina e junção amelo-dentinária; e para a presença ou ausência de imagem dupla. Os resultados foram submetidos à correlação de Spearman, análise de variância e teste de Tukey. Os tempos de 20s a 130s apresentaram qualidade satisfatória em todos os quesitos abordados. Após esta primeira avaliação, os seis tempos considerados estatisticamente eficazes nos quesitos referentes à qualidade geral da imagem foram submetidos a uma nova avaliação, quanto à presença de cárie proximal. As imagens correspondentes aos tempos selecionados foram interpretadas por cinco avaliadores. Cada avaliador atribuiu um escore para cada uma das faces dentárias interpretadas. Esses escores foram posteriormente comparados ao padrão ouro. Os tempos de dessensibilização alternativos foram avaliados, quanto à sua acurácia no diagnóstico de cárie, por meio da curva ROC. As médias das curvas ROC correspondentes aos tempos de dessensibilização avaliados variaram de 0,61 a 0,66 e não apresentaram diferença estatística significativa entre elas. O desempenho dos tempos de dessensibilização alternativos de 20s a 130s foi satisfatório tanto nos quesitos de qualidade geral da imagem como no diagnóstico de cáries proximais, demonstrando a possibilidade da utilização de tempos alternativos de dessensibilização das placas do sistema DenOptix na redução do tempo de trabalho na clínica diária / Abstract: The aim on this study was to verify if DenOptix¿s phosphor plates alternative erasing times would cause any influence on the image quality and on the diagnosis of approximal caries. Ten human teeth phantoms were radiographed using phosphor plates, partially erased. The chosen erasing times were: 130s, 98s, 66s, 34s, 25s, 20s, 15s, 10s, 5s e 0s. Two observers, independently, evaluated the general quality of each image, scoring the images on contrast, density, sharpness and structures definition (enamel, dentine and enamel-dentine junction). The presence of double image was also evaluated. The resultant data was evaluated using the Spearmen¿s correlation, variance analysis, and Tukey¿s test. The erasing times from 20s to 130s had a satisfactory quality in all the evaluated items. After the first evaluation, the erasing times that showed statistical efficiency in the evaluated quality items of the image went through another evaluation regarding the presence of approximal caries. The images of the selected erasing times were evaluated by five observers. Each observer scored the approximal surfaces of each tooth. The scores were compared to the golden standard. The alternative erasing times were evaluated by their accuracy on predicting caries by means of the ROC curve analysis. The means of the ROC curves of each erasing time evaluated varied from 0,61 to 0,66 and did not show significant statistical difference between them. The alternative erasing times from 20s to 130s was satisfactory both on the quality analysis as on approximal caries diagnosis, what makes the use of those alternative erasing times of DenOptix¿s phosphor plates feasible during clinical practice / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289203
Date28 February 2007
CreatorsMelo, Daniela Pita de
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Tosoni, Guilherme Monteiro, Scaf, Gulnara, Campos, Paulo Sérgio Flores
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Radiologia Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format62f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.003 seconds