Desenvolvimento de uma bancada para a realização de ensaios de auto-amortecimento em cabos condutores de energia elétrica

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, 2015. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2015-11-25T15:01:39Z
No. of bitstreams: 1
2015_TúlioAvelarGuimarães.pdf: 4903299 bytes, checksum: 3b2f645aa77f5285f5df38df1dab1655 (MD5) / Approved for entry into archive by Marília Freitas(marilia@bce.unb.br) on 2016-05-26T19:35:24Z (GMT) No. of bitstreams: 1
2015_TúlioAvelarGuimarães.pdf: 4903299 bytes, checksum: 3b2f645aa77f5285f5df38df1dab1655 (MD5) / Made available in DSpace on 2016-05-26T19:35:24Z (GMT). No. of bitstreams: 1
2015_TúlioAvelarGuimarães.pdf: 4903299 bytes, checksum: 3b2f645aa77f5285f5df38df1dab1655 (MD5) / O presente trabalho tem como objetivo o desenvolvimento de uma bancada para a realização de ensaios de auto-amortecimento em cabos condutores de energia elétrica. Para isso, foi realizado um estudo sobre os conceitos utilizados nas metodologias para a obtenção da potência dissipada pelo condutor, buscando recomendações de entidades mundialmente atuantes em pesquisas envolvendo condutores e linhas de transmissão, dentre elas: CIGRE, IEEE e EPRI. Problemas para a realização dos ensaios foram levantados e soluções adotadas ou propostas. Foi verificado que a massa da parte vibrante do shaker eletromecânico era alta em relação à massa por unidade de comprimento do condutor. Para diminuir a influência do peso concentrado do excitador, que modifica a resposta em frequência do cabo, foi desenvolvido um projeto para uma conexão flexível entre o shaker e o condutor, apresentado também neste trabalho. Ensaios preliminares foram realizados para verificar a consistência da metodologia utilizada e aplicabilidade da bancada para a obtenção de resultados de auto-amortecimento de condutores. Foram utilizadas duas metodologias diferentes: O Método da Potência e o Método da Onda Estacionária. A análise dos dados destes testes mostrou uma boa proximidade entre os resultados das duas metodologias, além de vários fenômenos esperados, como o aumento da potência dissipada com o aumento da frequência de ensaio ou da amplitude de vibração. Os ensaios também revelaram oportunidades de melhoria na bancada e foram feitas propostas para implementação. Além disso, foram feitos testes para a verificação da influência da rigidez da conexão nos dados obtidos para o auto-amortecimento utilizando o Método da Potência. Estes testes revelaram um aumento nos valores de potência dissipada obtidos para configurações mais rígidas. / This work aims the development of a test bench to carry out self-damping measurements on conductors of electric energy. For this, a study was conducted on the concepts used in the methodologies for obtaining the power dissipated by the cable, searching recommendations of globally active institutions on research involving drivers and transmission lines, such as: CIGRE, IEEE and EPRI. Problems for the tests were raised and solutions were adopted or proposed. It was found that the mass of the vibrating part of the electromechanical shaker was high relative to the mass per unit length of the conductor. To reduce the influence of the weight concentrated on the driver, which modifies the frequency response of the cable, a flexible connection between the shaker and the conductor has been developed, also presented in this work. Preliminary tests were performed to verify the consistency of the used methodology and the applicability of the bench to obtain conductor self-damping results. Two different methodologies were used: The Power Method and the Inversed Standing Wave Method. The analysis of the data from these tests showed similar results for both methodologies, and various expected phenomena such as the increase of power dissipation with increasing of frequency or amplitude of vibration. The tests also showed improvement opportunities on the bench and were made proposals for implementation. In addition, tests were performed to verify the influence of connection rigidity on data obtained for the self-damping using the Power Method. These tests showed an increase in power dissipated values obtained for configurations that are more rigid.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unb.br:10482/20547
Date30 September 2015
CreatorsGuimarães, Túlio Avelar
ContributorsFerreira, Jorge Luiz de Almeida
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UnB, instname:Universidade de Brasília, instacron:UNB
RightsA concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data., info:eu-repo/semantics/openAccess