Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, 2009. / Submitted by Jaqueline Ferreira de Souza (jaquefs.braz@gmail.com) on 2011-02-28T11:27:59Z
No. of bitstreams: 1
2009_TaniaMariadeOliveiraSerraHortencio.pdf: 16223040 bytes, checksum: 7ab702a94bb1bed964b9e8298d1026d4 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2011-02-28T11:51:28Z (GMT) No. of bitstreams: 1
2009_TaniaMariadeOliveiraSerraHortencio.pdf: 16223040 bytes, checksum: 7ab702a94bb1bed964b9e8298d1026d4 (MD5) / Made available in DSpace on 2011-02-28T11:51:28Z (GMT). No. of bitstreams: 1
2009_TaniaMariadeOliveiraSerraHortencio.pdf: 16223040 bytes, checksum: 7ab702a94bb1bed964b9e8298d1026d4 (MD5) / O presente trabalho é de natureza experimental e, visa apresentar uma contribuição sobre o estudo da estimativa de vida útil de cabos condutores de energia elétrica, tendo como referência a análise da resistência à fadiga por fretting. Em particular, o levantamento de dados preliminares que possibilitem a determinação da curva de durabilidade (Curva de Wöhler ou S-N) da montagem do cabo CAA 397,5 MCM - IBIS, com o grampo de suspensão monoarticulado, assim como, identificar as características associadas ao aspecto e posicionamento das falhas encontradas neste tipo de cabo. Testes a uma mesma amplitude de tensão foram conduzidos, observando-se a ruptura do primeiro, segundo e terceiro fio de alumínio e registrando-se o número de ciclos experimentado pela montagem até o instante de cada quebra. Repetindo-se o teste para diferentes amplitudes de deslocamento pode-se então traçar uma curva da amplitude de tensão contra o número de ciclos, a qual é denominada de Curva S-N ou de Wöhler. Para estabelecer a tensão gerada na região de falha utilizou-se a fórmula de Poffenberger-Swart (1965).Os ensaios foram executados, de acordo com as recomendações da CIGRE (1985), EPRI (1979) e IEEE (1978), em uma bancada de 46,8 metros de comprimento, em ambiente climatizado, com sistema de controle dos equipamentos totalmente informatizado.Para a combinação cabogrampo usada, a Curva Limite de Segurança da CIGRÉ (CSBL) mostrou-se muito conservativa, isto é, a vida do cabo é de 5 a 10 vezes maior quando calculada utilizando a curva específica do material como referência.Através do mapeamento das falhas contatouse que para amplitudes de deslocamento menores que 1,0 mm, de maneira geral as falhas ocorreram na camada externa, já para amplitudes maiores a maior incidência até três falhas, foi na camada interna. O valor médio das distâncias das falhas na camada externa foi de 26,7 mm e na camada interna foi de 26,2 mm. Esta constatação evidencia que a previsão da vida útil em fadiga do cabo é de grande importância para as atividades de manutenção, isto porque, as quebras dos fios ocorrem dentro do grampo de suspensão e, portanto não podem ser identificadas nas inspeções visuais. _______________________________________________________________________________ ABSTRACT / The present wok consists of an experimental research on fretting fatigue of an ACSR IBIS overhead conductor, with the objective to contribute to the study of the estimated fatigue life of such components. More specifically, tests were conducted in the same bending displacement amplitude (peak to peak) at a position on the cable 89 mm away from the last point of contact between cable and the mono-articulated aluminium clamping system. The rupture of the first, second and third aluminum strands were monitored as well as the number of cycles experienced by the assembly until the moment of each break. Repeating the test for different levels of prescribed displacement amplitudes one can then plot a curve of stress amplitude versus fatigue life, the so called S-N or Wöhler`s Curve. To correlate the prescribed displacement with stress amplitude Poffenberger-Swart equation was used. The tests were performed in accordance with the recommendations of CIGRE (1985), EPRI (1979) and IEE (1978), in a 46.8 meters long span, in air conditioned environment and using a closed loop control system to assure the repeatability of the tests. The results of the tests showed that, for the conductor/clamp mounting used, the CIGRE Safe Border Line (CSBL) curve was extremely conservative. The actual conductor life was 5 to 10 times higher than the value estimated by the CSBL for the same level of stress amplitude. Such result emphasizes the need to raise specific laboratory S-N curves for different cable/clamp assemblies should accuracy of life estimates be pursued. Mapping the wire failures it was found that for displacement amplitudes smaller than 1 mm, the failures generally occurred in the outer layer, while for amplitudes larger than 1 mm, they preferably occurred in the inner aluminium layer, for up to three failures. Such wire breaks were localized inside the clamp at average distances of 26.7 mm in the outer layer and 26.2 mm in the inner layer, both measured from the clamp mouth. The fact that the broken strand occurs well within the suspension clamp means that it can not be identified by visual inspection and that even inspections by infrared thermography may not be effective, demonstrating the need to establish an accurate methodology to estimate the remaining conductor life in order to allow maintenance before a cathastrofic breakage of the whole cable.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unb.br:10482/6951 |
Date | 28 September 2009 |
Creators | Hortêncio, Tânia Maria de Oliveira Serra |
Contributors | Araújo, José Alexander |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UnB, instname:Universidade de Brasília, instacron:UNB |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0034 seconds