Submitted by Ivone Costa (mivone@ufpa.br) on 2018-09-05T14:51:22Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AvaliacaoQualidadeAgua.pdf: 1998206 bytes, checksum: d6f32f22b6271357ca76b2f45bd1f455 (MD5) / Approved for entry into archive by Ivone Costa (mivone@ufpa.br) on 2018-09-05T14:51:57Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AvaliacaoQualidadeAgua.pdf: 1998206 bytes, checksum: d6f32f22b6271357ca76b2f45bd1f455 (MD5) / Made available in DSpace on 2018-09-05T14:51:57Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AvaliacaoQualidadeAgua.pdf: 1998206 bytes, checksum: d6f32f22b6271357ca76b2f45bd1f455 (MD5)
Previous issue date: 2017-09-18 / Este trabalho teve como objetivo principal analisar a qualidade de água de chuva em
uma unidade experimental de captação e tratamento de água de chuva (UETAC) com
ênfase no tratamento por filtração em dois diferentes meios filtrantes: areia mais
carvão ativado de caroço de açaí (misto) e carvão ativado de caroço de açaí. A
pesquisa foi desenvolvida em três etapas: 1) montagem dos dois filtros e
caracterização dos meios filtrantes; 2) monitoramento da qualidade de água de chuva
na UETAC, considerando as variáveis cor aparente, turbidez, condutividade elétrica,
pH, alcalinidade total, coliformes totais e E.coli, e a investigação da presença de
microrganismos no reservatório; 3) avaliação dos custos envolvidos na implantação
do sistema, considerando as duas alternativas de filtração. A areia apresentou
diâmetro efetivo de 0,62mm, coeficiente de uniformidade de 1,42 e massa específica
de 2.632 kg/m3. O carvão ativado teve diâmetro efetivo de 6,9mm, coeficiente de
uniformidade de 0,73, umidade de 2,10% e densidade aparente de 0,358 g/cm3. O
filtro de carvão ativado apresentou vazão de 0,35 m³/h, sendo superior ao filtro misto
(0,20 m³/h), assim como a taxa de filtração foi maior (34,26 m³/m2.dia) e a do filtro
misto de 19,19 m³/m2.dia. O telhado contribuiu na degradação da qualidade de água
de chuva, aumentando os valores de cor aparente, turbidez, condutividade elétrica e
alcalinidade total em relação a água atmosférica, o que já era esperado; a
autolimpeza não apresentou desempenho favorável, já que houve aumento no valor
das variáveis cor aparente, turbidez, coliformes totais e E. Coli em comparação com a
água coletada após o telhado; o reservatório foi a unidade do sistema que melhor
contribuiu para a melhoria da qualidade de água da chuva, onde houve a diminuição
de valores das variáveis cor aparente, turbidez e condutividade elétrica em relação a
água após a autolimpeza; o filtro misto e o filtro de carvão ativado não tiveram
desempenho favorável, já que interferiram negativamente na qualidade de água vinda
do reservatório para todas as variáveis analisadas. O filtro misto alcançou resultados
melhores do que o filtro de carvão ativado. O filtro misto também foi a melhor
alternativa no sistema considerando o custo de implantação. Na reservação foram
encontrados cerca de 7 microrganismos diferentes, entre eles: zooplânctons, frústulas
de algas e esporos de fungos. A UETAC não produziu água de chuva para fins
potáveis, pois houve presença de microrganismos patogênicos, além de ter valores de
variáveis acima do limite da portaria 2914 (BRASIL, 2011), havendo a necessidade de
desinfecção no final do processo de tratamento. / This research has main objective to analyze the rainwater quality in an experimental
unit of rainwater harvesting and treatment (EURHT) with emphasis on the treatment by
filtration in two different filters: sand plus activated carbon of açaí seed (mixed) and
activated carbon of açaí seed. The research was developed in three steps: 1)
installation of the two filters and characterization of the filter composition; 2) rainwater
quality monitoring of EURHT, considering the variables: apparent color, turbidity,
electrical conductivity, pH, total alkalinity, total coliforms and E.coli, and the
investigation of the presence of microorganisms in the tank; 3) evaluation of the costs
involved in the implementation of the system, considering two filtration alternatives.
The sand had effective diameter of 0.62mm, uniformity coefficient of 1.42 and specific
gravity of 2,632 kg/m3. Activated carbon had an effective diameter of 1.8mm,
coeficiente uniformity of 0.58, a humidity of 2.10%, and density of 0.358 g/cm3.
Activated carbon filter had a flow rate of 0.35 m³/h, higher than the mixed filter (0.20
m³/h), even as the filtration rate was higher (34.26 m³/m2.d) and the Mixed filter of
19.19 m³/m2.d. The roof contributed to rainwater quality degradation, increasing the
values of apparent color, turbidity, electrical conductivity and total alkalinity in relation
to atmospheric water, which was already expected; The self-cleaning didn’t had a
proptious performance, because there was increase in the variables value apparent
color, turbidity, total coliforms and E. Coli in relation to water collected after the roof;
The tank was the part of system that best contributed to the improvement of rainwater
quality, because there was a decrease in the variables value apparent color, turbidity
and electrical conductivity in relation to water after self-cleaning; The mixed filter and
the activated carbon filter didn’t had a proptious performance, because decrease the
water quality arriving from the tank for all variables. The mixed filter get better results
than activated carbon filter. The mixed filter was also the best financial alternative in
the system. In the tank were found about 7 different microorganisms, between them:
zooplankton, algae frustules and fungal spores. EURHT didn’t produce rainwater for
drinking purposes, because there were pathogenic microorganisms, besides values of
variables above the limit of the ordinance 2914 (BRASIL, 2011), and there is a
requirement for disinfection at end of the treatment process.
Keywords: Rainwater haversting. Rainwater quality. Rainwater filtration
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/10190 |
Date | 18 September 2017 |
Creators | PACHECO, Paulo Rodrigo da Costa |
Contributors | TEIXEIRA, Luiza Carla Girard Mendes |
Publisher | Universidade Federal do Pará, Programa de Pós-Graduação em Engenharia Civil, UFPA, Brasil, Instituto de Tecnologia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | 1 CD ROM, reponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0194 seconds