Return to search

Aspectos tecnicos da cateterização do seio coronariano baseado no componente atrial do eletrograma intracavitario durante o procedimento de implante de marcapasso biventricular / Technical aspects of coronary sinus catheterization based on the atrial component of the intracavitary eletrogram and radiological anatomy during implantation procedure of a biventricular pacemaker

Orientador: Orlando Petrucci Junior / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-11T10:51:42Z (GMT). No. of bitstreams: 1
Souza_FernandoSergioOlivade_D.pdf: 1025341 bytes, checksum: 15ba5e4c6177129ac03b697eb1f59cb9 (MD5)
Previous issue date: 2008 / Resumo: A estimulação elétrica biventricular apresenta bons resultados no tratamento da insuficiência cardíaca congestiva refratária em portadores de cardiomiopatia dilatada com distúrbios de condução interventricular. OBJETIVO: Apresentar proposição utilizando técnica original simplificada para o implante de eletrodo de estimulação ventricular esquerda epicárdica, baseado na anatomia radiológica e no eletrograma intracavitário,enfatizando o componente atrial, demonstrando o resultado, complicações, ressaltando tempo total de utilização de fluoroscópio. CASUÍSTICA E MÉTODO: De Outubro de 2001 a Março de 2007 foram realizados 234 implantes de marca-passo biventricular em pacientes previamente selecionados, utilizando-se anatomia radiológica e observação de eletrograma intracavitário, dando-se prioridade ao componente atrial, demonstrando a taxa de sucesso, complicações e tempo total de utilização de radioscopia. RESULTADOS: O implante do sistema, utilizando-se a estimulação do ventrículo esquerdo via seio coronariano não foi possível em 19(8,1%) pacientes. Em 30(12,8%) pacientes foram observadas dificuldades na canulação do óstio coronário e em 52(22%) pacientes observaram-se dificuldades de progressão do eletrodo através do seio coronário. O tempo médio de utilização de radioscopia foi 18,69(±15,2) min. CONCLUSÃO: A utilização da técnica simplificada para cateterização do seio coronário sem utilização de bainha, baseada na anatomia radiológica e no eletrograma intracavitário, enfatizando o componente atrial, no tratamento de portadores de cardiomiopatia dilatada avançada, pela terapia de ressincronização cardíaca, demonstrou resultado satisfatório, índice de complicações pequeno, e baixa exposição do operador a radiação ionizante / Abstract: Biventricular pacing has present good results in treatment of congestive cardiac heart failure in patients with dilated miocardyopathy and interventricular conduction disturbance. PURPOSE: to present a proposal of using a original simplified technique for left epicardial ventricular lead stimulation, based on the radiological imaging of the anatomy and intracavitary electrogram, emphasizing the atrial component, showing the results, complications, highlighting the total fluoro time. METHODS: From October, 2001 up to March, 2007, 234 biventricular pacemaker implantations were performed in previously selected patients, using radiological anatomy and observation of the intracavitary electrogram, focusing on the atrial component, and showing the success rate, complications and total time of radioscopy utilization. RESULTS: The implantation of the system using left ventricular pacing via coronary sinus was not possible in 19(8,1%) patients. Difficulties on the cannulation of the coronary ostium were felt in 30(12,8%) patients and difficulties of lead advancement through the coronary sinus were felt in 52(22%) patients. The mean time of radioscopy utilization was 18.69(±15,2) min. CONCLUSION: the use of a simplified technique for coronary sinus cannulation without the aid of a sheath, based on the radiological imaging of the anatomy and intracavitary electrogram, emphasizing the atrial component, for the treatment of advanced dilated cardiomyopathy patients with cardiac resynchronization therapy, has shown satisfactory results, low incidence of complications, and low exposure of the operator to ionizing radiation / Doutorado / Cirurgia / Doutor em Cirurgia

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/311523
Date17 April 2008
CreatorsSouza, Fernando Sergio Oliva de
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Petrucci Junior, Orlando, 1966-, Junior, Orlando Petrucci, Dinkhuysen, Jarbas Jackson, Vasconcelos, Jose Tarcisio Medeiros de, Lopes, Luiz Roberto, Toro, Ivan Felizardo Contrera
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Ciências Médicas, Programa de Pós-Graduação em Cirurgia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format52f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0215 seconds