Return to search

Achieving Low Emissions from a Biogas Fuelled SI Engine Using a Catalytic Converter

A spark ignition engine was retrofitted to operate on biogas fuel. Biogas was synthetically generated through the mixing of various pure gases. The air-fuel ratio was accurately controlled using a closed feedback system consisting of flow controllers and a wide range oxygen sensor. A
natural gas catalytic converter was implemented with the use of biogas fuel. To achieve full NOx and CO reduction the engine was required to run at a slightly rich equivalence ratio. Methane emissions posed to be the hardest to reduce across the catalyst. The biogas fuel composition had
no effect on the catalyst performance. The catalyst performance was only affected by exhaust temperature and equivalence ratio. The catalyst requires tight A/F ratio control for optimal performance. A Catalytic converter can be used to reach low emissions but requires the knowledge of the biogas fuel composition.