This master thesis deals with design of grate biomass boiler with 50 t/h power. A fuel of the boiler is a mixture of contaminated biomass and woodchips. The boiler produces steam with parameters of 4,2 MPa and 420 °C. Stochiometric and thermal calculations are based on given fuel composition and output steam parameters. Heat exchangers are designated in accordance with the calculations. General drawing of the boiler is attached to this document. Anti-corrosion measures are considered, due to chlorine content in biomass. Hydraulic and aerodynamic losses and dew point of the flue gas is calculated in the end.
Identifer | oai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:417540 |
Date | January 2020 |
Creators | Vrána, Jakub |
Contributors | Křemínský, Pavel, Lisý, Martin |
Publisher | Vysoké učení technické v Brně. Fakulta strojního inženýrství |
Source Sets | Czech ETDs |
Language | Czech |
Detected Language | English |
Type | info:eu-repo/semantics/masterThesis |
Rights | info:eu-repo/semantics/restrictedAccess |
Page generated in 0.002 seconds