Return to search

Determina??o de sildenafila (Viagra?) e carbamazepina em formula??es farmac?uticas por amperometria de m?ltiplos pulsos em sistema FIA / Determination of sildenafil (Viagra?) and carbamazepine in pharmaceutical formulations by multiple pulses amperometry in FIA system

Submitted by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2015-02-19T13:03:28Z
No. of bitstreams: 5
carlos.pdf: 2538374 bytes, checksum: bc72a52cc529db58b3cf890bd9a41042 (MD5)
license_url: 52 bytes, checksum: 3d480ae6c91e310daba2020f8787d6f9 (MD5)
license_text: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
license.txt: 2110 bytes, checksum: b4c884761e4c6c296ab2179d378436d4 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2015-02-20T09:21:34Z (GMT) No. of bitstreams: 5
license.txt: 2110 bytes, checksum: b4c884761e4c6c296ab2179d378436d4 (MD5)
carlos.pdf: 2538374 bytes, checksum: bc72a52cc529db58b3cf890bd9a41042 (MD5)
license_url: 52 bytes, checksum: 3d480ae6c91e310daba2020f8787d6f9 (MD5)
license_text: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2015-02-20T09:21:34Z (GMT). No. of bitstreams: 5
license.txt: 2110 bytes, checksum: b4c884761e4c6c296ab2179d378436d4 (MD5)
carlos.pdf: 2538374 bytes, checksum: bc72a52cc529db58b3cf890bd9a41042 (MD5)
license_url: 52 bytes, checksum: 3d480ae6c91e310daba2020f8787d6f9 (MD5)
license_text: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Previous issue date: 2013-02-21 / O presente trabalho apresenta m?todos simples, r?pidos e de baixo custo para determina??o de citrato de sildenafila (CS) e carbamazepina (CBZ) em formula??es farmac?uticas atrav?s da detec??o amperom?trica de m?ltiplos pulsos (MPA) em sistema de an?lise por inje??o em fluxo (FIA) utilizando como eletrodo de trabalho o diamante dopado com boro (DDB). O m?todo para determina??o de CS consiste na aplica??o de tr?s pulsos de potencial em sequ?ncia. Os pulsos de potencial de 1,6 V e 1,9 V s?o utilizados para detec??o eletroqu?mica do f?rmaco e um terceiro pulso de potencial (1,0 V) para promover a limpeza e reativa??o da superf?cie do eletrodo de DDB. Os limites de detec??o (LD) obtido nas condi??es estabelecidas est?o na ordem de 10 nmol L-1 para ambos os potenciais de detec??o. O desvio padr?o relativo das respostas de 10 inje??es consecutivas de CS na concentra??o de 4,5x10-5 mol L-1 foi de 0,1 e 0,2% para os pulsos de potencial de detec??o de 1,9 V e 1,6 V, respectivamente. Os estudos de adi??o e recupera??o de CS padr?o foram realizados em todas as amostras farmac?uticas apresentando recupera??o, em todos os casos, pr?ximo de 100%. Os resultados de doseamento dos medicamentos realizados a partir do m?todo proposto foram validados por metodologia cromatogr?fica. Para a CBZ foram propostas duas vertentes anal?ticas, uma voltada para determina??o do ativo em amostras farmac?uticas e outra para detec??o do f?rmaco em fluidos biol?gicos. Alguns par?metros foram semelhantes em ambos os procedimentos, s?o eles: eletr?lito suporte (?cido sulf?rico 0,2 mol L-1), vaz?o (3,0 mL min-1), volume de amostragem (150 ?L), potencial de limpeza (-1,4 V) e tempo de aplica??o deste potencial (600 ms). Al?m destes par?metros, para an?lise do f?rmaco em produto farmac?utico, foram utilizados para detec??o os pulsos de potenciais 1,6 e -1,2V, sendo aplicados por 150 e 30 ms, respectivamente. Nestas condi??es, foram obtidas as seguintes faixas lineares de trabalho: 0,6 a 40,0 ?mol L-1 para o pulso de potencial de 1,6 V e 0,4 a 20,0 ?mol L-1 para o pulso de potencial de -1,2 V. Para determina??o de CBZ em fluido biol?gico adotou-se como sistema de detec??o o pulso de potencial de 1,6 V aplicado por 800 ms (gerador) e o pulso de potencial de -1,2 V aplicado por 30 ms (detector). Para este pulso de potencial foi obtida faixa linear de trabalho de 0,02 a 1,0 ?mol L-1 e LD de 1,78 nmol L-1. Os estudos de adi??o e recupera??o de CBZ padr?o em amostras farmac?uticas e urina apresentaram resultados pr?ximos de 100%. Os resultados do ensaio de doseamento de medicamentos, realizados pelo m?todo proposto, foram validados por meio de metodologia oficial. Este trabalho apresenta, pela primeira vez, m?todos para determina??o de CS e CBZ em formula??es farmac?uticas atrav?s da detec??o MPA em sistema FIA. A associa??o desta t?cnica ao eletrodo de trabalho de DDB permitiu o desenvolvimento de m?todos de elevada sensibilidade, seletividade, rapidez e reprodutibilidade, demonstrando not?vel potencialidade para aplica??o no controle de qualidade de rotina de CS e CBZ em laborat?rios farmac?uticos e farm?cias de manipula??o. / Disserta??o (Mestrado) ? Programa de P?s-Gradua??o em Qu?mica, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2012. / ABSTRACT

The present work presents simple, fast and low-cost methods for determination of sildenafil citrate (CS) and carbamazepine (CBZ) in pharmaceutical formulations using flow injection analysis (FIA) with multiple pulse amperometric (MPA) detection on the boron-doped diamond (DDB) working electrode. The method for the CS determination consists of the application of three sequential potential pulses as function of the time. SC is detected at 1.6 V and 1.9 V by two different irreversible oxidation processes. The third potential pulse (1.0 V) is applied for the regeneration (cleaning) of the electrode (boron-doped diamond) surface. The limit of detection (LD) in an order of 10 nmol L-1 was reached with a standard deviation of less than 0.2 % (n = 10) for 4.5 x 10-5 mol L-1 CS. The analytical frequency was calculated in 86 injections per hour. The addition-recovery studies in all the samples were around 100% and the results were validated by chromatographic methods. For the CBZ determination, two analytic conditions were proposed, one used for determination of a drug in pharmaceutical samples and other for detection the active ingredient in biological fluids. Some parameters were similar in both procedures, they are: supporting electrolyte (sulfuric acid 0.2 mol L-1), flow (3.0 ml min-1), sampling volume (150 ?L), regeneration potential pulse (-1.4 V) and time of application of this potential (600 ms). In addition to these parameters, for analysis of pharmaceutical drug, were used to detect it the potential pulses 1.6 V and -1.2 V, being applied for 150 and 30 ms, respectively. These conditions provided linear range of 0.6 to 40.0 ?mol L -1 for potential pulse 1.6 V and 0.4 to 20.0 ?mol L-1 for potential pulse -1.2 V. For the CBZ determination in biological fluid adopted as detection system the potential pulse of 1.6 V applied for 800 ms (generator) and potential pulse of -1.2 V applied for 30 ms (detector). For this potential pulse the linear range was of 0.02 to 1.0 ?mol L-1 and the LD was 1.78 nmol L-1. The addition-recovery studies in all the samples were around 100 % and the results were validated by official method. This work presents for the first time methods of SC and CBZ determination in pharmaceutical formulations utilizing MPA detection coupled to an FIA system. This technique, associated with a BDD working electrode, provided a sensitive, selective, fast and highly reproducible methods. Thus, the proposed methods may be an extremely attractive alternative for routine large and small-scale CS and CBZ analysis.

Identiferoai:union.ndltd.org:IBICT/oai:acervo.ufvjm.edu.br/jspui:1/500
Date27 July 2012
CreatorsLopes J?nior, Ant?nio Carlos Vieira
ContributorsSantos, Wallans Torres Pio dos, Richter, Eduardo Mathias, Ferreira, Lucas Franco, Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM), Santos, Wallans Torres Pio dos
PublisherUFVJM
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFVJM, instname:Universidade Federal dos Vales do Jequitinhonha e Mucuri, instacron:UFVJM
RightsA concess?o da licen?a deste item refere-se ao ? termo de autoriza??o impresso assinado pelo autor, assim como na licen?a Creative Commons, com as seguintes condi??es: Na qualidade de titular dos direitos de autor da publica??o, autorizo a Universidade Federal dos Vales do Jequitinhonha e Mucuri e o IBICT a disponibilizar por meio de seus reposit?rios, sem ressarcimento dos direitos autorais, de acordo com a Lei n? 9610/98, o texto integral da obra disponibilizada, conforme permiss?es assinaladas, para fins de leitura, impress?o e/ou download, a t?tulo de divulga??o da produ??o cient?fica brasileira, e preserva??o, a partir desta data., info:eu-repo/semantics/openAccess

Page generated in 0.0124 seconds