Return to search

Avaliação do efeito de diferentes agentes clareadores na rugosidade superficial e estabilidade de cor de dois compósitos / In vitro evaluation of different bleaching agents on the roughness and color stability of two dental composites

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo foi avaliar, in vitro, o efeito de dois clareadores a base de peróxido de hidrogênio a 10% e a 35%, Rembrandt Whitening Pen/Oral B e Whiteness HP Maxx/FGM na estabilidade de cor e rugosidade superficial de dois compósitos, sendo um nanohíbrido TPH3/ Dentsply e outro nanoparticulado Filtek Z350/3M ESPE. Foram confeccionados 40 corpos de prova a partir de uma matriz de aço inox com dimensões de 21,0 mm de diâmetro e 2,00 mm de profundidade e divididos em dois grupos conforme o compósito a ser avaliado e submetidos aos seguintes experimentos: Exp. I Ação dos agentes clareadores na estabilidade de cor dos compósitos; Exp. II - Ação dos agentes clareadores na rugosidade superficial dos compósitos; Exp. III - Ação do polimento de superfície na rugosidade superficial e retomada de cor dos compósitos. Tanto a rugosidade como a estabilidade de cor foi avaliada em rugosímetro Mitutoyo SJ 201P e Espectofotômetro de Reflectância Perkin Elmer Lambda 35 UV/VIS respectivamente durante as seguintes etapas do experimento: T0 - após a confecção dos corpos de prova, T1 - após envelhecimento acelerado das amostras por 24 horas por luz ultravioleta, T2 - após submetidas a dois corantes: café e açaí por 7 dias, T3 - após submetidas aos agentes clareadores e T4- após polimento das mesmas. Durante todo o experimento os corpos de prova foram mantidos em saliva artificial e estufa calibrada a 37oC. Os resultados foram tratados estatisticamente por ANOVA e testes de Tukey, comparações múltiplas de Bonferroni e SNK com 5% de significância. Não foram observadas diferenças estatisticamente significantes entre os corantes, o mesmo acontecendo quando os clareadores foram comparados por Teste-t de Student com 5% de significância. Baseado nos resultados obtidos pôde-se concluir que o compósito TPH3 foi mais afetado pelos corantes que o compósito Z350. Os agentes clareadores não foram capazes de promover clareamento dos compósitos nos tempos testados, porém o polimento possibilitou retorno à condição de cor inicial (envelhecida) para o compósito TPH3 o mesmo não acontecendo para o Z350. O polimento não determinou retorno à condição original de rugosidade para qualquer dos compósitos. / The objective of this study was to evaluate, in vitro, the effects of two commercially available bleaching agents containing hydrogen peroxide, Rembrandt Whitening Pen/Oral B and Whiteness HP Maxx/FGM, on the surface roughness and on color change of two composites (TPH3/Dentsply and Filtek Z350/3M ESPE). Twenty specimens of each material were constructed by using a stainless matrix, measuring 21.0 mm diameter and 2.00 mm depth and divided in three groups according the experiments. Group I- effect of the bleaching agents on the composites color change; Group II- effect of the bleaching agents on surface roughness; Group III- effect of polishing procedures on the surface roughness and on color change of the composites. The color measurements were done using a reflectance spectrophotometer Perkin Elmer Lambda 35 UV/VIS according to the CIE L*a*b* color scale and the roughness measurements were obtained using a digital Mitutoyo rugosimeter SJ 201P. The measurements were made in five times: T0: after the specimen preparation; T1: after accelerated aging for 24 hours UV light; T2: after immersed for 07 days at 37o C in either coffee or açaí (a typical fruit of North of Brazil); T3: after bleaching procedures and T4: after finishing and polishing. The results were statistical treated by ANOVA and the differences treated by Tukey, Bonferroni`s test and SNK with 5% of significance. According t-Test with 5% of significance, there were no differences between the staining (coffee and açaí) and neither between the bleaching agents tested. The composite TPH3 showed higher values of discoloration when compared with Filtek Z350, The bleaching agents were not able to improve any kind of whitening on the composites surface. The polishing procedures after bleaching were effective on return the TPH3 to its original color, but they were not capable to return the original roughness of both of the composites.

Identiferoai:union.ndltd.org:IBICT/urn:repox.ist.utl.pt:UERJ:oai:www.bdtd.uerj.br:846
Date13 February 2009
CreatorsAnna Paula Kalix França Mendes
ContributorsKatia Regina Hostilio Cervantes Dias, Rodrigo Sant'Anna Aguiar dos Reis, Marcos de Oliveira Barceleiro, Hélio Rodrigues Sampaio Filho, Paulo Sergio Souza da Silva, Márcio Antônio Paraizo Borges, Hilda Maria Montes Ribeiro de Souza
PublisherUniversidade do Estado do Rio de Janeiro, Programa de Pós-Graduação em Odontologia, UERJ, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Formatapplication/pdf
Sourcereponame:Biblioteca Digital de Teses e Dissertações da UERJ, instname:Universidade do Estado do Rio de Janeiro, instacron:UERJ
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0029 seconds