Return to search

Flue gas desulphurisation under South African conditions.

D. Tech. Mechanical Engineering. / Investigates and/or rank the performance of locally available materials (i.e. limestone, dolomite, or calcrete) as sorbents in the capture of SO2 emissions from coal-fired power plants. Two experimental procedures were adopted in this work: the pH-stat method was used to simulate conditions encountered in wet flue gas desulphurisation (WFGD); and the fixed-bed reactor was used to simulate conditions encountered in the dry in-duct flue gas desulphurisation (DFGD) process. It is important to note that most studies of using calcium-based materials as sorbents for SO2 removal have been carried out in overseas countries. These studies were carried out using materials and research conditions prevailing in the particular countries. Furthermore, all South African coal-fired power stations burn low grade coal allowing the high grade coal to be exported. As a result, coal-fired power stations in South Africa emit higher emissions than the overseas power stations which are operated on high grade coals. Thus the results achieved internationally may not be directly translated to the South African conditions.

Identiferoai:union.ndltd.org:netd.ac.za/oai:union.ndltd.org:tut/oai:encore.tut.ac.za:d1000444
Date January 2010
CreatorsSiagi, Otara Zachary.
ContributorsMbarawa, M. M., Kolesnikov, A. V., Van der Riet, Mark
Source SetsSouth African National ETD Portal
LanguageEnglish
Detected LanguageEnglish
TypeText
FormatPDF