Return to search

Avaliação da introdução de cogeração no sistema isolado do interior do estado do Amazonas / Evaluation of the introduction of cogeneration to the Amazon state isolated power system

Orientadores: Silvia Azucena Nebra e Elizabeth Ferreira Cartaxo / Tese (doutorado) - Universidade Estadual se Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-04T02:01:08Z (GMT). No. of bitstreams: 1
Cruz_RicardoWilsonAguiarda_D.pdf: 17244783 bytes, checksum: a03d0eedccd3e72d383d8e704276c5cf (MD5)
Previous issue date: 2004 / Resumo: Neste trabalho procurou-se apresentar um panorama da geração isolada de energia elétrica pelo Sistema CEAM, quanto às suas características técnicas e econômicas, e do mercado de conservação de pescado do interior do Estado do Amazonas, como bases para desenvolver um método que permita avaliações da introdução de cogeração nessas usinas, visando a produção de mo e gelo, como forma de elevação da lucratividade. Para tanto é mostrado que uma usina autônoma produzindo apenas energia elétrica no cenário interiorano amazonense não tem como ser lucrativa no cenário atual. Foi utilizado como ferramentas básicas elementos da teoria dos motores de combustão interna sob carga variável, teoria das máquinas de remgeração por absorção água-amônia e métodos termoeconômicos baseados na primeira e segunda lei da Termodinâmica. O quadro típico das usinas do interior é mostrado por dados coletados em visitas a cinco usinas, sendo duas delas de outros estados que não o Amazonas, mas que conservam características comuns com as usinas amazonenses. O mercado de pescado é discutido sobre dados bibliográficos. E, do cruzamento desses quadros, são inferidas características da interdependência entre remgeração industrial e energia elétrica / Abstract: This investigation shows a panorama of the isolated power generation of the Amazon State CEAM System regarding its technical and economic characteristics, as well as the problems of the refrigeration facilities of the tishing industry of inland the State, focusing to develop methods to evaluate the introduction of cogeneration in the generation system to the enhance its protitability. Meanwhile, it is shown that a autonomous power station can not expect to become protitable in the Amazonian nowadays scenario if it uniquely produces electric energy. To achieve this objective the main theoretical background were elements of the theory of internal combustion engines under variable charge, the theory of aquammonia absorption refiigeration devices, and methods belonging to thermoeconomics based on tirst law and second law of thermodynamics. A typical profile of the stations of the CEAM System is showed by collected data on tive autonomous power stations among the Northern Brazilian autonomous power grid. The tive power stations preserve common characteristics among them. The market of the tishing industry is showed by bibliography surveyed data. These data made possible to infer the profound relationship between refiigeration and electric energy / Doutorado / Planejamento de Sistemas Energeticos / Doutor em Planejamento de Sistemas Energéticos

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/265238
Date03 February 2004
CreatorsCruz, Ricardo Wilson Aguiar da
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Cartaxo, Elizabeth Ferreira, Nebra, Silvia Azucena, 1943-, Pereira, José Tomaz Vieira, Bajay, Sérgio Valdir, Velasquez, Jose Antonio Andres, Guerra, Helvio Neves
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Mecânica, Programa de Pós-Graduação em Planejamento de Sistemas Energéticos
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format228p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0019 seconds