Return to search

Avaliação da colapsibilidade e resistência de ponta em um solo arenoso compactado de Petrolina-PE com e sem inundação

Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-12-01T14:03:53Z
No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Dissertação Klayde Versão 9 - revisão final.pdf: 9120386 bytes, checksum: d27cc83b0c7db013e2bf497f74e2a430 (MD5) / Made available in DSpace on 2016-12-01T14:03:53Z (GMT). No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Dissertação Klayde Versão 9 - revisão final.pdf: 9120386 bytes, checksum: d27cc83b0c7db013e2bf497f74e2a430 (MD5)
Previous issue date: 2016-05-05 / CNPQ / A colapsibilidade dos solos é um fenômeno típico de solos porosos, quando saturados
apresentam variação de volume, podendo provocar danos significativos nas obras de
engenharia, comprometendo total ou parcialmente estas obras. A ocorrência de solos
colapsíveis é observado em vários municípios do Estado de Pernambuco, e em particular
no Município de Petrolina. A investigação geotécnica e o entendimento de como se
processa o fenômeno é imprescindível para a elaboração de projetos e a diminuição de
possíveis danos às construções assentadas sobre esse tipo de solo. O objetivo desse
trabalho é avaliar a variação de volume e de resistência de ponta com e sem inundação
em solo compactado. A variação de volume devido à inundação foi avaliada utilizando
ensaios edométricos simples e duplo e a resistência de ponta por meio de penetrômetro
estático, em solo de um Conjunto Habitacional do Programa Minha Casa, Minha Vida,
localizado no Município de Petrolina-PE, nos graus de compactação de 80%, 85%, 90%
e 95% e nas umidades natural (0,22%), 4,00% e 7,00%. O solo é essencialmente arenoso
com mais de 90% de sua composição de areia, fração argilosa < 8% e praticamente sem
presença de silte. O solo é mau graduado (CU < 5%), não liquido e não plástico, se
enquadra no grupo SM (Areia Siltosa) na classificação do SUCS o valor máximo do
potencial de colapso atingido nos ensaios edométricos simples foi de 13,41% na tensão
de 640 kPa no solo com GC 80% e umidade de 4,00% e o valor mínimo foi de 0,24,00%
na tensão de 10 kPa, GC 95% e umidade de 7,00%. Os valores dos potenciais de colapso
(CP) diminuem com o acréscimo de umidade inicial e grau de compactação. A sua
resistência de ponta cresce com o aumento do grau de compactação, umidade e
profundidade, atingindo valor de 19,17 MPa para GC = 95% e umidade 7,00%. Há perda
de resistência de ponta durante o processo de inundação que depende da umidade inicial
e grau de compactação e há acréscimo, no solo saturado após o colapso. A variação de
volume e a resistência de ponta devido à variação de inundação são influenciadas pelo
grau de compactação e umidade inicial do solo. / The collapsibility soil is a typical phenomenon of porous soil when saturated present
volume variation, which can cause significant damage to the engineering works,
committing all or part of these works. The occurrence of collapsible soils is observed in
several municipalities in the state of Pernambuco, and in particular in the city of Petrolina.
Geotechnical investigation and understanding of how processes if the phenomenon is
essential for the development of the project and the reduction of possible damage to
buildings settled on this type of soil. The aim of this study is to evaluate the change in
volume and tip resistance with flooding in compacted soil. The volume change due to
flooding was assessed using single and double oedometric tests and tip resistance through
static penetrometer in soil of a housing program of the Minha Casa, Minha Vida, located
in the city of Petrolina, in degrees compretion of 80%, 85%, 90% and 95% and the natural
moisture (0.22%), 4.00% and 7.00%. The soil is mainly sandy with more than 90% of its
sand composition, clay fraction < 8% and virtually no presence of silt. The soil is poorly
Graduate (CU <5%), not liquid and not plastic, falls within the SM group (silty sand) in
classification SUCS. collapsing the maximum value of the potential in achieving simple
oedometric assays was 13.41% at 640 kPa in the ground stress to GC 80% moisture and
4.00% and the minimum value was 0, 24,00% at 10 kPa pressure, GC 95% and humidity
of 7.00%. The values of the collapse potential (CP) decrease with the initial moisture
increase and degree of compaction. Its tip resistance increases with increasing the degree
of compaction, humidity and depth, reaching a value of 19.17 MPa GC = 95% moisture
and 7.00%. There is loss of peak strength during the flooding process that depends on the
initial moisture content and degree of compaction and there is an increase in the saturated
soil after collapse. The volume change and the tip resistance due to flood variations are
influenced by the degree of compaction and soil initial moisture.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufpe.br:123456789/18059
Date05 May 2016
CreatorsVERÍSSIMO, Klayde Janny da Silva
Contributorshttp://lattes.cnpq.br/8035357058902261, FERREIRA, Silvio Romero de Melo
PublisherUniversidade Federal de Pernambuco, Programa de Pos Graduacao em Engenharia Civil, UFPE, Brasil
Source SetsIBICT Brazilian ETDs
LanguageBreton
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFPE, instname:Universidade Federal de Pernambuco, instacron:UFPE
RightsAttribution-NonCommercial-NoDerivs 3.0 Brazil, http://creativecommons.org/licenses/by-nc-nd/3.0/br/, info:eu-repo/semantics/openAccess

Page generated in 0.002 seconds