Return to search

Cold-Formed Steel Member Connections Using BAC Screw Fasteners

In this project, the main research objective is intend to seek criteria for evaluating the capacity of BAC screw fasteners with mixed configuration of waterproof seal washer, sealer tape and different pre-drill holes to determine shear and tension strength values for the screws used in cold-formed steel connections. The thesis presents the design methods and test program conducted to investigate the behavior and strength of the screw connections in shear and tension test. Test results were compared with AISI design provisions to determine if new design equations will be developed for those screws used in BAC cooling tower applications. LRFD resistance factors and ASD safety factors were investigated to the proposed design equations.

Identiferoai:union.ndltd.org:unt.edu/info:ark/67531/metadc1505166
Date05 1900
CreatorsLi, Xun
ContributorsYu, Cheng, Anaya, Leticia, Manzo, Maurizio (Aerospace and mechanical engineer)
PublisherUniversity of North Texas
Source SetsUniversity of North Texas
LanguageEnglish
Detected LanguageEnglish
TypeThesis or Dissertation
Formatx, 62 pages, Text
RightsUse restricted to UNT Community, Li, Xun, Copyright, Copyright is held by the author, unless otherwise noted. All rights Reserved.