Submitted by Maicon Juliano Schmidt (maicons) on 2015-07-20T14:17:58Z
No. of bitstreams: 1
Ronaldo Bueno de Souza.pdf: 1999281 bytes, checksum: 5dd2b3645a9e4750a12f291e30ba6d41 (MD5) / Made available in DSpace on 2015-07-20T14:17:58Z (GMT). No. of bitstreams: 1
Ronaldo Bueno de Souza.pdf: 1999281 bytes, checksum: 5dd2b3645a9e4750a12f291e30ba6d41 (MD5)
Previous issue date: 2015-04-07 / CYTED - Programa Iberoamericano de Ciencia y Tecnología para el Desarrollo / Este trabalho apresenta o estudo de um sistema de refrigeração por absorção assistido por energia solar térmica com intuito de ser empregado no arrefecimento de uma pousada de ecoturismo localizada em um local remoto, desprovida de conexão à rede elétrica. Para o estudo do sistema proposto foi utilizado o software de simulações TRNSYS, onde em uma etapa inicial do trabalho foi realizada a comparação dos resultados do software com os resultados dos modelos matemáticos dos componentes do sistema de refrigeração. Foi desenvolvido um modelo computacional, para realização de simulações horárias que permitiu a simulação de três configurações de sistemas de refrigeração por absorção, podendo assim determinar a influência dos componentes e parâmetros utilizados no sistema no uso da energia auxiliar e no atendimento da carga térmica. O primeiro modelo é constituído por um sistema onde a água aquecida pelo coletor solar térmico e é armazenada em um reservatório térmico, sendo a mesma utilizada para a alimentação do chiller de absorção. A água gelada produzida pelo chiller é armazenada em outro reservatório térmico onde fica disponível para o consumo. Neste modelo observa-se que com o uso de 120 m² de coletores de tubo evacuado chega-se a índices de atendimento dos consumos superiores a 87 %. O segundo modelo é similar ao primeiro, com a inclusão de um aquecedor auxiliar para a água de alimentação do chiller de absorção. Neste modelo observou-se que com o uso de 120 m² de coletores de placas planas chega-se a um consumo de energia auxiliar inferior a 195 GJ, e com o uso de 120 m² de coletores de tubo evacuado chega-se a um consumo de energia auxiliar inferior a 150 GJ. O terceiro modelo é similar ao segundo, onde foi acrescentado um sistema para utilização da água de arrefecimento do chiller de absorção, para uso no consumo de água quente para banho, nos chuveiros. Neste modelo observa-se que o aproveitamento da água de arrefecimento não afeta o consumo de energia auxiliar, se comparado com o consumo do segundo modelo. / This paper presents the study of a cooling system for absorption assisted by solar energy with a view to be used in the cooling of an ecotourism lodge located in a remote location, devoid of connection to the grid. To study the proposed system was used TRNSYS simulation software, where in an initial work step of comparing software results with the results of mathematical models of the components of the refrigeration system is performed. A computer model was developed to perform simulations slot which simulated three configurations absorption refrigeration systems and can therefore determine the influence of the components and system parameters used in the auxiliary power usage and meet the thermal load. The first model is made up of a system where the water heated by the solar thermal collector and is stored in a thermal storage tank, being the same used for feeding the absorption chiller. The chilled water produced by the chiller is stored in another thermal reservoir where it is available for consumption. In this model it is observed that with the use of 120 m² evacuated tube collectors comes to fuel consumption attendance rates of over 87 %. The second model is similar to the first, with the inclusion of an auxiliary heater to supply water from the absorption chiller. In this model we found that with the use of 120 m² of flat plate collectors comes to an auxiliary power consumption of less than 195 GJ, and with the use of 120 m² evacuated tube collectors we arrive at a consumption of auxiliary power less than 150 GJ. The third model is similar to the second, which was added to a system using the cooling water from absorption chiller for use in the consumption of hot water for baths, showers on. In this model, it is observed that the use of the cooling water does not affect the auxiliary power consumption compared with the consumption of the second model.
Identifer | oai:union.ndltd.org:IBICT/oai:www.repositorio.jesuita.org.br:UNISINOS/4571 |
Date | 07 April 2015 |
Creators | Souza, Ronaldo Bueno de |
Contributors | http://lattes.cnpq.br/9219989574784501, Macagnan, Mario Henrique, Copetti, Jacqueline Biancon |
Publisher | Universidade do Vale do Rio dos Sinos, Programa de Pós-Graduação em Engenharia Mecânica, Unisinos, Brasil, Escola Politécnica |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UNISINOS, instname:Universidade do Vale do Rio dos Sinos, instacron:UNISINOS |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0022 seconds