Return to search

A influencia do calçado de salto alto sobre a lordose lombar associada aos musculos lombares e gstrocnemio / The influence of high heel shoes on lumbar lordosis associated to the lumbar muscles and gastrocnemios

Orientador: Paulo Henrique Ferreira Caria / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T14:11:06Z (GMT). No. of bitstreams: 1
Casarin_CezarAugustoSouza_M.pdf: 406484 bytes, checksum: 9c5e962f1f2458381ce5e607bc1431ef (MD5)
Previous issue date: 2005 / Resumo: Nas últimas décadas as mulheres vêm conquistando posições de destaque na sociedade ocidental o que exigiu novos cuidados com a aparência e os calçados de salto alto se tornaram um dos símbolos da feminilidade contemporânea. Discrepâncias entre a literatura popular e a científica a respeito da influencia do uso de calçados de salto alto no aumento da lordose lombar, bem como a atividade dos músculos lombares e gastrocnêmio durante o uso desses calçados, suscitaram essa pesquisa. A qual teve como objetivo analisar o ângulo da curvatura lombar da coluna vertebral, por meio de imagens digitais (ICC = 0.96), através do programa ALCIMAGEM e investigar a atividade eletromiográfica dos músculos longuíssimo dorsal e íliocostal lombar (eretores da espinha) e do músculo gastrocnêmio, bilateralmente. Foram avaliadas vinte e quatro voluntárias descalças e calçando sapatos com saltos de 1 cm, 5 cm e 10 cm de altura, de diferentes modelos, divididas em grupo (1) usavam sapatos de salto alto diariamente e grupo (2) não usavam sapatos de salto alto diariamente. Os valores em graus foram submetidos à análise de variância ANOV A e ao teste de TUKEY. Os dados eletromiográficos foram submetidos ao teste de FRIEDMAN e ao teste de MANN-WHITNEY. Os resultados apresentaram a ocorrência da retificação da lordose lombar, não havendo diferenças estatisticamente significativas entre os grupos (p>0,05). O maior ângulo de retificação lombar e a maior atividade eletromiográfica dos músculos analisados foram alcançados com o salto fino de 10 cm de altura. O músculo gastrocnêmio mostrou-se mais ativo eletromiograficamente e o grupo (1) apresentou maior atividade eletromiográfica que o (2). Conclui-se que o uso de calçados de salto alto não gera hiperlodose lombar, os músculos da perna foram mais ativos que os paravertebrais e que o grupo de mulheres que usa salto alto diariamente, apresentou maior atividade muscular dentre os músculos avaliados / Abstract: In the last deeades the women are oeeupying positions that previously were exclusively maseuline, what put them in prominenee position in the western soeiety. The largest exhibition raised larger eare with the appearanee and the high hell shoes are one of the symbols of the eontemporary femininity. The popular literature refers to the high heel shoes as eausers of the inerease of the lumbar lordosis, in eompensation the scientifie literature shows the reetifieation of that eurvature. Diserepancies also appeared in relation to the aetivity of the muscles spine ereetors and gastroenêmius, when if did use of high heel shoes. The present work had as objeetive analyzes the angle of the lumbar eurvature of the spine through digital images (ICC = 0.96) through the program ALCIMAGEM and to investigate the eleetromyographie aetivity of the muscles longuissimus dorsal and ilioeostalis lumbar (spine ereetors) as well as the portions lateral and medial of the muscle gastroenêmius, bilaterally. Were evaluate twenty four volunteers barefoot and putting on shoes with high heels of 1 em, 5 em and 10 em of height and of different models, divided in group (1) they used high heel shoes daily and group (2) they didn't use high heel shoes daily. The results presented the oeeurrenee of the reetifieation of the lumbar lordosis, not having differenees signifieants among the groups (p>0,05). The largest reaehed angle of lumbar reetifieation was with the shoe of fine high heels of 10 em of height. The muscle gastroenêmius was shown more eleetromyographie aetivate. The group (1) it presented higher eleetromyographie aetivity than group 2. Was eoncluded that the use of high heel shoes doesn't generate lumbar hiperlordosis, the muscles leg were more eleetromyographie aetive eompared to the low baek muscles and the women used high heel shoes daily it presented higher eleetromyographie activity / Mestrado / Biologia e Patologia Buco-Dental / Mestre em Anatomia

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288451
Date03 April 2005
CreatorsCasarin, Cezar Augusto Souza
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Caria, Paulo Henrique Ferreira, 1972-, Oliveira, Ana Maria Siriani de, Bigaton, Delaine Rodrigues
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format41 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0023 seconds