Return to search

Contribui??es para estrat?gia de controle aplicada ? gera??o fotovoltaica interconectada ? rede el?trica

Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2016-06-10T00:04:44Z
No. of bitstreams: 1
ThiagoDeOliveiraAlvesRocha_TESE.pdf: 3728978 bytes, checksum: e47856c08795ec056c30763c0e338dad (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2016-06-10T23:32:23Z (GMT) No. of bitstreams: 1
ThiagoDeOliveiraAlvesRocha_TESE.pdf: 3728978 bytes, checksum: e47856c08795ec056c30763c0e338dad (MD5) / Made available in DSpace on 2016-06-10T23:32:23Z (GMT). No. of bitstreams: 1
ThiagoDeOliveiraAlvesRocha_TESE.pdf: 3728978 bytes, checksum: e47856c08795ec056c30763c0e338dad (MD5)
Previous issue date: 2015-12-09 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / Os sistemas de gera??o, que utilizam fontes renov?veis, est?o se tornando cada vez
mais populares devido ? necessidade do incremento do uso da energia el?trica. Atualmente,
as fontes renov?veis cooperam com a gera??o convencional, em decorr?ncia da
limita??o do sistema na entrega da pot?ncia requerida, da necessidade da redu??o dos
efeitos indesejados das fontes que utilizam combust?veis fosseis (polui??o) e a dificuldade
de constru??o de novas linhas de transmiss?o e/ou distribui??o. Esta coopera??o se d? por
meio da gera??o distribu?da. Desta forma, neste trabalho s?o propostas contribui??es para
o sistema de controle utilizado para a interconex?o de sistemas PV (do ingl?s, Photovoltaic)
de gera??o distribu?da com a rede el?trica trif?sica, por meio de filtros de conex?o
do tipo LCL. A compensa??o da qualidade de energia no ponto de acoplamento comum
(PAC) ? realizada garantindo-se que a rede el?trica forne?a, ou consuma apenas pot?ncia
ativa e que suas correntes possuam baixo teor harm?nico. Diferentemente das t?cnicas
tradicionais, que necessitam de esquemas para a detec??o harm?nica, a t?cnica utilizada
realiza a compensa??o harm?nica sem a utiliza??o desses esquemas, controlando as correntes
de sa?da do sistema de uma forma indireta. Para que haja um efetivo controle da
tens?o do barramento CC (Corrente Cont?nua) ? utilizado o controlador robusto em modo
dual DSM-PI (Proporcional Integral Dual em Modo Deslizante), que durante o transit?rio
se comporta como um controlador em modo deslizante SM-PI (Proporcional Integral
em Modo Deslizante), e em regime permanente se comporta como um PI (Proporcional
Integral) convencional. Para o controle das correntes ? utilizado a estrat?gia de controle
repetitivo, onde s?o utilizados controladores de dupla sequ?ncia (DSC) sintonizados na
componente fundamental, no quinto e no s?timo harm?nico. As correntes de refer?ncia
s?o alinhadas ao ?ngulo de fase do vetor tens?o da rede el?trica, obtido a partir do uso
de um SRF-PLL (do ingl?s, Synchronous Reference Frame Phase-Locked-Loop). Com
o intuito de obter a m?xima pot?ncia do array fotovoltaico ? utilizado um algoritmo de
MPPT (do ingl?s, Maximum Power Point Tracking) sem a necessidade de adi??o de sensores.
Resultados experimentais s?o apresentados para demonstrar a efic?cia do sistema
de controle proposto. / Generation systems, using renewable sources, are becoming increasingly popular due
to the need for increased use of electricity. Currently, renewables sources have a role
to cooperate with conventional generation, due to the system limitation in delivering the
required power, the need for reduction of unwanted effects from sources that use fossil
fuels (pollution) and the difficulty of building new transmission and/or distribution lines.
This cooperation takes place through distributed generation. Therefore, this work proposes
a control strategy for the interconnection of a PV (Photovoltaic) system generation
distributed with a three-phase power grid through a connection filter the type LCL. The
compensation of power quality at point of common coupling (PCC) is performed ensuring
that the mains supply or consume only active power and that his currents have low distorcion.
Unlike traditional techniques which require schemes for harmonic detection, the
technique performs the harmonic compensation without the use of this schemes, controlling
the output currents of the system in an indirect way. So that there is effective control
of the DC (Direct Current) bus voltage is used the robust controller mode dual DSMPI
(Dual-Sliding Mode-Proportional Integral), that behaves as a sliding mode controller
SM-PI (Sliding Mode-Proportional Integral) during the transition and like a conventional
PI (Proportional Integral) in the steady-state. For control of current is used to repetitive
control strategy, which are used double sequence controllers (DSC) tuned to the fundamental
component, the fifth and seventh harmonic. The output phase current are aligned
with the phase angle of the utility voltage vector obtained from the use of a SRF-PLL
(Synchronous Reference Frame Phase-Locked-Loop). In order to obtain the maximum
power from the PV array is used a MPPT (Maximum Power Point Tracking) algorithm
without the need for adding sensors. Experimental results are presented to demonstrate
the effectiveness of the proposed control system.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufrn.br:123456789/20679
Date09 December 2015
CreatorsRocha, Thiago de Oliveira Alves
Contributors31804683434, http://lattes.cnpq.br/6628177274865696, Roda, Valentin Obac, 59464305800, http://lattes.cnpq.br/4823406157799513, Lima, Antonio Marcus Nogueira, 29158761420, http://lattes.cnpq.br/2237395961717699, Limongi, Leonardo Rodrigues, 03161890493, http://lattes.cnpq.br/3424760452548457, Costa, Fl?vio Bezerra, Ribeiro, Ricardo L?cio de Ara?jo
PublisherUniversidade Federal do Rio Grande do Norte, PROGRAMA DE P?S-GRADUA??O EM ENGENHARIA EL?TRICA E DE COMPUTA??O, UFRN, Brasil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Sourcereponame:Repositório Institucional da UFRN, instname:Universidade Federal do Rio Grande do Norte, instacron:UFRN
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0021 seconds