Return to search

Influencia dos ciclos termicos e mecanicos na resistencia de união de restaurações classe II em resina composta confeccionadas com tres sistemas adesivos / Influence of thermal and mechanical load cycling on bond strength of Class II composite resin restorations using three adhesive systems

Orientador : Giselle Maria Marchi Baron / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T02:47:56Z (GMT). No. of bitstreams: 1
Mitsui_FabioHiroyukiOgata_D.pdf: 4372212 bytes, checksum: 0f847604a188d129f752d02dbdae8281 (MD5)
Previous issue date: 2005 / Resumo: O objetivo deste estudo foi avaliar a influência da aplicação de ciclos térmicos e de carga mecânica na resistência de união à microtração, em restaurações de resina composta em cavidades Classe II do tipo ¿slot¿ vertical, com margem em dentina, confeccionadas com três sistemas adesivos. Cento e sessenta e oito cavidades foram preparadas nas superfícies proximais de dentes bovinos e distribuídas, aleatoriamente, de acordo com o sistema adesivo a ser aplicado (Single Bond, OptiBond Solo Plus e Clearfil SE Bond). Após a restauração das cavidades, utilizando o compósito resinoso Filtek Z250, foi realizada nova distribuição dos dentes, de acordo com o tipo de tratamento (térmico / mecânico) aos quais os dentes foram submetidos, formando dessa maneira 21 grupos experimentais no total (n=8): I - sem tratamento (controle), II - 100.000 ciclos mecânicos (CM), III - 200.000 CM, IV - 500.000 CM, V - 100.000 CM + 1000 ciclos térmicos (CT), VI - 200.000 CM + 1000 CT, VII - 500.000 CM + 1000 CT. A ciclagem térmica submeteu os espécimes a banhos de 60 segundos, a temperaturas de 5 e 55oC. Já o teste de ciclagem mecânica foi realizado mediante aplicação de força axial de 80N e freqüência de 2Hz. Após os ensaios de ciclagem, as restaurações sofreram três cortes seriados, perpendicularmente à parede cervical das restaurações, de forma a obter-se duas fatias no centro da restauração com espessuras de 0,8 a 1mm cada. As fatias obtidas foram desgastadas precisamente em lados opostos da interface adesiva, determinando-se uma área de secção transversal de 0,8 a 1mm2. Todos os espécimes obtidos foram submetidos ao teste de microtração a uma velocidade de 0,5 mm/min até a fratura. Após o ensaio, as duas porções fraturadas de cada espécime foram avaliadas em MEV para análise dos padrões de fratura. Os valores de resistência de união (MPa) foram submetidos à análise de variância 3 fatores e teste Tukey, com nível de significância de 5%. Para a análise dos protocolos de envelhecimento em relação aos grupos controles de cada adesivo, foi aplicado o teste de Dunnett ao mesmo nível de significância de 5%. O sistema adesivo autocondicionante apresentou médias de resistência de união significativamente menores em relação aos adesivos que preconizam o condicionamento total (p<0,0001) e, além disso, os espécimes restaurados com esse adesivo não resistiram à aplicação de 200.000 e 500.000 CM associados à CT. A efetividade dos protocolos de envelhecimento realizadas no estudo variou de acordo com o sistema adesivo avaliado, sendo que a aplicação de 100.000 ciclos de carga isoladamente não acarretou em uma diminuição significativa das médias de resistência de união. O padrão de fratura variou de acordo com o grupo analisado, tendo sido verificado todos os tipos de fratura nos espécimes avaliados. Na medida em que se aumentavam as tensões (ciclagens térmica e mecânica) a que os espécimes foram submetidos, diminuiu o número de fratura na interface e aumentou o percentual das fraturas mistas / Abstract: The aim of this study was to evaluate the influence of thermal and mechanical loading cycling on microtensile bond strength of Class II composite restorations in dentin, with three adhesive systems. One hundred and sixty eight slot vertical cavities were prepared on proximal surfaces of bovine teeth, and divided according to the adhesive system used (Single Bond, OptiBond Solo Plus, and Clearfil SE Bond). All cavities were filled with Filtek Z250 composite resin. Following restorative procedures, the teeth were once again allocated into different groups according to the thermal / mechanical treatment, thus obtaining 21 experimental groups (n=8): I - control, II - 100,000 mechanical cycles, III - 200,000 mechanical cycles, IV - 500,000 mechanical cycles, V - 100,000 mechanical cycles + 1,000 thermal cycles, VI - 200,000 mechanical cycles + 1,000 thermal cycles, VII - 500,000 mechanical cycles + 1,000 thermal cycles. Thermal cycling was performed by submitting the specimens to alternating 5o and 55oC baths, with a dwell time of 60 seconds in each bath. The teeth were then submitted to mechanical load cycling with an occlusal force of 80N at a frequency of 2Hz. The restorations were sectioned perpendicular to the cervical bonded interface into two 0.8-1mm thick slabs. The slabs were trimmed at the interface with a fine diamond bur in order to obtain a cross-sectional surface area of 0.8-1mm2. All specimens were then subjected to microtensile testing, at a cross-head speed of 0.5 mm/min, until failure of the specimens. The fractured surfaces were observed with a scanning electron microscope (SEM) to evaluate the fracture mode. Microtensile bond strength mean values (MPa) were subjected to ANOVA 3-way and Tukey¿s test, at significance level of 5%. The Dunnett¿s test was used in order to compare the groups that were submitted to load and thermal cycling with the control groups of each adhesive system (p<0.05). The self-etching primer presented lower bond strength mean values when compared to the total-etch systems (p<0.0001). In addition, the specimens restored with the self-etching primer did not resist to 200,000 e 500,000 load cycles associated with thermal cycling. The effectiveness of the aging protocols performed in this study showed different behavior according to the adhesive system evaluated. The application of only 100,000 load cycles did not present significant lower bond strength mean values. Failure modes varied according to the analyzed group, and all failures modes were verified in the fractured specimens. The number of mixed failures increased and the percentage of interphase failures decreased when the amount of thermal/mechanical cycles applied was higher / Doutorado / Dentística / Doutor em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289121
Date16 March 2005
CreatorsMitsui, Fabio Hiroyuki Ogata
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Marchi, Giselle Maria, 1970-, Francci, Carlos Eduardo, Junior, Sillas Luiz Lordelo Duarte, Paulillo, Luis Alexandre Maffei Sartini, Correr Sobrinho, Lourenço
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format78f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0044 seconds