Freeze-thaw durability of high strength silica fume concrete

Specimens from 27 batches of concrete with water to cementitious (cement plus silica fume) ratio of 0.25 to 0.32, with and without entrained air, were tested for freeze-thaw durability in accordance with ASTM C666, procedure A (freezing and thawing in water). In addition, another set of similar specimens were moist cured for 28 days instead of 14 days and tested in accordance with ASTM C666 , Procedure A to determine the effect of curing time on the freeze-thaw durability of high strength concrete. Results show that non air-entrained high strength concrete with water cementitious ratio of less than 0.30, regardless of the length of curing time, is frost resistant. Non-air-entrained concrete with water-cement ratio of 0.32 is also durable if silica fume is not used. / Ph. D.

Identiferoai:union.ndltd.org:VTETD/oai:vtechworks.lib.vt.edu:10919/53942
Date January 1988
CreatorsKashi, Mohsen Gholam-Reza
ContributorsCivil Engineering, Weyers, Richard E., Walker, Richard D., Barker, Richard M., Kuppusamy, Thangavelu, Swift, George W.
PublisherVirginia Polytechnic Institute and State University
Source SetsVirginia Tech Theses and Dissertation
Languageen_US
Detected LanguageEnglish
TypeDissertation, Text
Formatx, 134 leaves, application/pdf, application/pdf
RightsIn Copyright, http://rightsstatements.org/vocab/InC/1.0/
RelationOCLC# 19736119

Page generated in 0.0019 seconds