Return to search

Conversor CA-CC bridgeless monofásico de estágio único com PFC baseado no conversor SEPIC operando no modo de condução contínuo / Single-phase bridgeless AC-DC converter with a single-stage with PFC based on SEPIC converter operating in the continuous conduction mode

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho é apresentado a análise de um conversor CA-CC Bridgeless monofásico de estágio único com correção de Fator de Potência, baseado no conversor SEPIC isolado com os interruptores do lado CA. Para que o conversor exerça a técnica de correção de fator de potência, pelo fato de estar operando no modo de condução contínuo (MCC), é necessário controlar a corrente de entrada. Sendo assim, o sistema de controle, comparado caso o conversor operasse no modo de condução descontínuo (MCD), fica mais complexo, resultando em uma desvantagem para operação em MCC. Porém, quando se trata de rendimento, como os níveis de pico de corrente são menores operando em MCC, se espera obter um rendimento mais elevado. Além disso, com os interruptores do lado CA o conversor apresenta um número menor de semicondutores no caminho da corrente durante um período de comutação, comparado com a topologia convencional, sendo mais um ponto positivo se tratando do rendimento do conversor. São apresentadas as etapas de operação do conversor, as formas de onda ideais, tanto em alta frequência quanto em baixa frequência, a análise matemática contendo as principais equações que regem o funcionamento do conversor e a simulação numérica comprovando a análise desenvolvida. O conversor foi projetado para uma tensão de entrada de 127V com tensão de saída igual a 200V, operando com uma frequência de comutação igual a 50kHz e uma potência entregue a carga igual a 300W. / In this paper is presented the analysis of a single-phase bridgeless AC-DC converter with a single-stage of power factor correction, based on an isolated SEPIC converter with AC-side switches. Wherefore the converter carry out the power factor correction technic, by the act of operating in the continuous conduction mode (CCM), it’s essential to control the input current. Therefore, the control system, compared to the converter operating in the discontinuous conduction mode (DCM), become more complex, resulting on a disadvantage for the CCM. Nevertheless, when it’s come to efficiency, how the levels of peak current are smaller operating in CCM, it is expected to obtain a higher efficiency. Besides that, with the AC-side switches the converter presents a smaller number of semiconductors on the current path during a switching period, compared with the conventional topology, become one more positive advantage for the converter efficiency. Are presented the operation stages of the converter, waveforms, for high frequency as well as mains frequency, the numeric analysis possessing the leading equations for the converter operations and the numeric simulation proving the developed analysis. The converter was designed for a 127V input voltage, with a 200V output voltage, operating with a switching frequency of 50kHz, and a 300W rated output power.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.utfpr.edu.br:1/3022
Date14 December 2017
CreatorsEwerling, Marcos Vinícius Mosconi
ContributorsFont, Carlos Henrique Illa, Costa, Paulo Junior Silva, Nascimento, Claudinor Bitencourt, Font, Carlos Henrique Illa
PublisherUniversidade Tecnológica Federal do Paraná, Ponta Grossa, Programa de Pós-Graduação em Engenharia Elétrica, UTFPR, Brasil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UTFPR, instname:Universidade Tecnológica Federal do Paraná, instacron:UTFPR
Rightsinfo:eu-repo/semantics/openAccess