Return to search

Demand-side management in office buildings in Kuwait through an ice-storage assisted HVAC system with model predictive control

Examining methods for controlling the electricity demand in Kuwait was the main objective and motivation of this researchp roject. The extensiveu se of air-conditioning for indoor cooling in office and large commercial buildings in Kuwait and the Gulf States represents a major part of the power and electricity consumption in such countries. The rising electricity generation cost and growing rates of consumption continuously demand the construction new power plants. Devising and enforcing Demand-SideM anagemen(t DSM) in the form of energye fficient operations trategies was the response of this research project to provide a means to rectify this situation using the demand-side management technique known as demand levelling or load shifting. State of the art demand-sidem anagementte chniquesh ave been examined through the developmenot f a model basedp redictive control optimisations trategyf or an integrateda ndm odulara pproachto the provisiono f ice thermals torage. To evaluate the potential of ice-storage assisted air-conditioning systems in flattening the demand curve at peak times during the summer months in Kuwait, a model of a Heating, Ventilation, and Air-conditioning (HVAC) plant was developed in Matlab. The model engaged the use of model based predictive control (MPQ) as an optimisation tool for the plant as a whole. The model with MPC was developed to chose and decide on which control strategy to operate the integrated ice-storage HVAC plant. The model succeeded in optimising the operation of the plant and introduced encouraging improvement of the performance of the system as a whole. The concept of the modular ice-storage system was introduced through a control zoning strategy based on zonal orientation. It is believed that such strategy could lead to the modularisation of ice-storage systems. Additionally, the model was examined and tested in relation to load flattening and demonstrated promising enhancement in the shape of the load curve and demonstrated flattened demand curves through the employed strategy. When compared with measured data from existing buildings, the model showed potential for the techniques utilised to improve the load factor for office buildings.

Identiferoai:union.ndltd.org:bl.uk/oai:ethos.bl.uk:422979
Date January 2005
CreatorsAl-Hadban, Yehya
ContributorsBatty, W. J.
PublisherCranfield University
Source SetsEthos UK
Detected LanguageEnglish
TypeElectronic Thesis or Dissertation
Sourcehttp://dspace.lib.cranfield.ac.uk/handle/1826/3885

Page generated in 0.0014 seconds