Return to search

Controle Repetitivo Discreto Aplicado A Um Inversor Monofásico Conectado à Rede Elétrica

Submitted by James Neves da Silva (james.silva@ufba.br) on 2018-03-06T13:34:55Z
No. of bitstreams: 1
Dissertacao_James_Final.pdf: 20562994 bytes, checksum: 297f9118e3898e9a7046b6dd9553c27a (MD5) / Approved for entry into archive by Vanessa Reis (vanessa.jamile@ufba.br) on 2018-03-13T15:39:09Z (GMT) No. of bitstreams: 1
Dissertacao_James_Final.pdf: 20562994 bytes, checksum: 297f9118e3898e9a7046b6dd9553c27a (MD5) / Made available in DSpace on 2018-03-13T15:39:09Z (GMT). No. of bitstreams: 1
Dissertacao_James_Final.pdf: 20562994 bytes, checksum: 297f9118e3898e9a7046b6dd9553c27a (MD5) / Este trabalho teve apoio financeiro da CAPES. / Este trabalho propõe um procedimento de projeto para um controlador repetitivo
discreto, com a fnalidade de controlar a corrente de saída de um inversor LC monofásico em ponte completa conectado à rede elétrica. O inversor também alimenta uma carga resistiva em derivação. O controlador assegura a estabilidade do sistema e robustez contra distorções harmônicas na tensão da rede. Sua concepção se baseia em um filtro notch de fase zero para compensar um pico de ressonância causado pelo filtro LC na
saída do inversor, dado que este pico pode levar o sistema à instabilidade. Obtémse margem de estabilidade apropriada por meio de um filtro passa-baixa empregado no
laço de realimentação positiva que faz parte do controlador. Simulações foram realizadas com auxílio dos softwares MATLAB e PSIM, para avaliar o desempenho do controlador sob diferentes condições de distorções harmônicas da tensão da rede. Além disso, para avaliar experimentalmente o controlador, foi utilizado um kit da Texas Instruments, que utiliza um DSP e contém um inversor em ponte completa e um filtro LC. Tanto as simulações quanto os experimentos laboratoriais mostraram que o controlador repetitivo opera corretamente, injetando corrente na rede de acordo com a referência fornecida ao sistema, e com robustez quanto às distorções harmônicas na tensão da rede. / This work proposes a designing procedure for a discrete repetitive controller governing the output current of a single-phase grid-connected LC full-bridge inverter. The
inverter also supplies a resistive local shunt load. The controller assures system stability
and robusteness to grid voltage harmonic distortions. Its design relies on a zero-phase
notch flter which compensates a resonant peak caused by the LC flter at the inverter’s output. Such peak may lead the system to instability. A proper stability margin is
reached through a low-pass flter employed in the positive feedback loop of the controller. Simulations using the PSIM and MATLAB softwares have been carried out to
access the controller performance under different harmonic conditions for the grid voltage. In addition, a DSP-based kit board from Texas Instruments containing a full-bridge LC inverter has been applied to experimentally test the controller. Both simulated and experimental results have been show that the repetitive controller works correctly, injecting current into the grid accordingly to the reference signal with robustness to voltage harmonic distortions.

Identiferoai:union.ndltd.org:IBICT/oai:192.168.11:11:ri/25525
Date01 December 2017
CreatorsSilva, James Neves da
ContributorsCosta, Fabiano Fragoso, Tahim, André Pires Nóbrega, Costa, Fabiano Fragoso, Tahim, André Pires Nóbrega, Fontana, Márcio, Ordoñez, Bernardo, de Castro, Alexandre Cézar
PublisherEscola Politécnica da Universidade Federal da Bahia, Programa de Pós-Graduação em Engenharia Elétrica, UFBA, brasil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFBA, instname:Universidade Federal da Bahia, instacron:UFBA
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0019 seconds