Return to search

CMOS system for high throughput fluorescence lifetime sensing using time correlated single photon counting

Fluorescence lifetime sensing using time correlated single photon counting (TCSPC) is a key analytical tool for molecular and cell biology research, medical diagnosis and pharmacological development. However, commercially available TCSPC equipment is bulky, expensive and power hungry, typically requiring iterative software post-processing to calculate the fluorescence lifetime. Furthermore, the technique is restrictively slow due to a low photon throughput limit which is necessary to avoid distortions caused by TCSPC pile-up. An investigation into CMOS compatible multimodule architectures to miniaturise the standard TCSPC set up, allow an increase in photon throughput by overcoming the TCSPC pile-up limit, and provide fluorescence lifetime calculations in real-time is presented. The investigation verifies the operation of the architectures and leads to the selection of optimal parameters for the number of detectors and timing channels required to overcome the TCSPC pile-up limit by at least an order of magnitude. The parameters are used to implement a low power miniaturised sensor in a 130 nm CMOS process, combining single photon detection, multiple channel timing and embedded pre-processing of the fluorescence lifetime, all within a silicon area of < 2 mm2. Single photon detection is achieved using an array of single photon avalanche diodes (SPADs) arranged in a digital silicon photomultiplier (SiPM) architecture with a 10 % fill-factor and a compressed 250 ps output pulse, which provides a photon throughput of > 700 MHz. An array of time-interleaved time-to-digital converters (TI-TDCs) with 50 ps resolution and no processing dead-time records up to eight photon events during each excitation period, significantly reducing the effect of TCSPC pile-up. The TCSPC data is then processed using an embedded centre-of-mass method (CMM) pre-calculation to produce single exponential fluorescence lifetime estimations in real-time. The combination of high photon throughput and real-time calculation enables advances in applications such as fluorescence lifetime imaging microscopy (FLIM) and time domain fluorescence lifetime activated cell sorting. To demonstrate this, the device is validated in practical bulk sample fluorescence lifetime, FLIM and simulated flow based experiments. Photon throughputs in excess of the excitation frequency are demonstrated for a range of organic and inorganic fluorophores for minimal error in lifetime calculation by CMM (< 5 %).

Identiferoai:union.ndltd.org:bl.uk/oai:ethos.bl.uk:676229
Date January 2013
CreatorsTyndall, David
ContributorsHenderson, Robert ; Renshaw, David
PublisherUniversity of Edinburgh
Source SetsEthos UK
Detected LanguageEnglish
TypeElectronic Thesis or Dissertation
Sourcehttp://hdl.handle.net/1842/12238

Page generated in 0.0012 seconds