Return to search

Contribuição a estimativa da cronotanatognose atraves da dosagem de ions potassio por analisador ion-seletivo no humor vitreo

Orientador: Eduardo Daruge / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-26T17:44:27Z (GMT). No. of bitstreams: 1
GaiottoJunior_OsmarAntonio_D.pdf: 3092477 bytes, checksum: 82e391d1a9f87bd2c2e0200b5bd8d0b8 (MD5)
Previous issue date: 2000 / Resumo: Este trabalho constituiu-se na determinação da concentração de íons potássio no humor vítreo de coelhos após a morte procurando correlaciona-la com a estimativa do tempo decorrido de morte. A coleta de humor vítreo foi realizada nos olhos de 40 ( quarenta) coelhos em intervalos de 2/2h iniciando-se com 2 horas até 12 horas após a morte. o mecanismo de morte foi trauma crânio encefálico seguido de decapitação de maneira idêntica em todos eles. Foi utilizada a técnica de dosagem íons de potássio através de analisador de eletrólitos íon seletivo e os resultados foram analisados estatisticamente. Os resultados demonstraram que ocorreu variação estatisticamente significativa na concentração de íons-potássio relacionada ao tempo decorrido de morte. Estes resultados foram comparados com aqueles obtidos com a técnica de fotometria de chama, levando-nos conclusão que os resultados pelo analisador íon-seletivo são mais específicos e tem mais acuracidade / Abstract: This study was built up on the determination of the potassium ion concentration at habits humor vitreous after it's death trying to correlate it with the death time estimation. The humor vitreous collection of forty habits was made during an interval of two hours starting with two hours until the first twelve hours after death. The death mechanism was a cranial traumatism followed by a decapitation in the same way for each of them. We performed the determination of potassium concentration by ion - selective analyzer and the results were studied by statistical methods, demonstrating that it has occurred a statically important variation in the potassium ion concentration related with the death time. This results were compared with those ones taken by the flame photometry technique, showing us that the results made by the ion - selective analyzer are more specific and have more accuracy / Doutorado / Doutor em Odontologia Legal e Deontologia

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/290725
Date30 May 2000
CreatorsGaiotto Junior, Osmar Antonio
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Daruge, Eduardo, 1933-2015, Massini, Nelson, Sampaio, Claudia Maria de Almeida, Gonçalves, Roberto José, Daruge Junior, Eduardo
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Odontologia Legal e Deontologia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format83f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0061 seconds