<p>Technical systems of today are often complex and integrated. If a fault occurs, the consequences can be disastrous both for the system itself and its surroundings. To maintain the operation and the security it is necessary to have a surveillance system which can detect a fault in an early stage.</p><p>In this thesis two structural methods for fault isolation analysis are discussed. The result from the studied algorithms shows what fault isolation properties a diagnostic model is expected to have. If the isolability is not good enough, it also gives information on where further modelling needs to be done. </p><p>To base a comparison of the two structural analysis algorithms on, four criteria are defined concerning for example realizability of residuals and time complexity. One interesting part of the methods is how dynamic models are handled. It is shown how differential constraints can end up in differential cycles which implies calculatory problems and what effects structural differentiation has on a system. </p><p>The algorithms have been tested on an application from the research training network DAMADICS. The result shows how different types of input models in this case give the same result.</p>
Identifer | oai:union.ndltd.org:UPSALLA/oai:DiVA.org:liu-2222 |
Date | January 2004 |
Creators | Rattfält, Linda |
Publisher | Linköping University, Department of Electrical Engineering, Institutionen för systemteknik |
Source Sets | DiVA Archive at Upsalla University |
Language | English |
Detected Language | English |
Type | Student thesis, text |
Relation | LiTH-ISY-Ex, ; 3462 |
Page generated in 0.0023 seconds