Return to search

Efeitos de agentes clareadores de alta concentração para tratamento em consultorio na microdureza, morfologia e composição quimica do esmalte humano / Effects of bleaching agents of high concentration for treatment in office in microhardness, morphology and chemical composition of human enamel

Orientador: Marcelo Giannini / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T05:38:41Z (GMT). No. of bitstreams: 1
Berger_SandrineBittencourt_M.pdf: 5356625 bytes, checksum: 1b4907c704681cbb071f3574823129e2 (MD5)
Previous issue date: 2007 / Resumo: Vários estudos têm se preocupado com os efeitos adversos produzidos pelos agentes clareadores de uso caseiro e de consultório. Este estudo tem como objetivo avaliar os efeitos de agentes clareadores de alta concentração (peróxido de hidrogênio a 35%) utilizados em consultório na dureza, composição química e estrutural do esmalte humano. Sessenta e cinco terceiros molares humanos hígidos foram utilizados. Dois fragmentos de esmalte (4x4x3mm) foram removidos das faces vestibular e lingual de cada dente. As amostras foram divididas em 10 grupos (n=10). Antes do clareamento, foram polidas e submetidas ao teste de microdureza Knoop (KHN) e análise em Espectroscopia Raman Transformada de Fourier (ERTF) para determinação da relação de fosfato (PO4) e carbonato (CO3) presente no esmalte não tratado. O grupo controle (GC) não foi submetido ao tratamento clareador. Nos grupos experimentais foram utilizados três diferentes agentes clareadores (Whiteness HP Maxx - W; Pola Office ¿ P e Opalescence Xtra - O) bem como três formas de irradiação (sem irradiação - SI; irradiação com lâmpada halógena ¿ LH, irradiação com LED + Laser Diodo - L). Após os tratamentos, os géis clareadores foram coletados com a solução de enxágüe para avaliação da concentração de cálcio, utilizando espectrofometria de absorção atômica. Em seguida, as amostras foram submetidas à ERTF, ao teste de microdureza superficial e interna, observadas em microscopia eletrônica de varredura para analisar as alterações na superfície e avaliadas em microscopia de luz polarizada para analisar os efeitos das técnicas de clareamento na desmineralização superficial do esmalte. As médias de microdureza superficial variaram de 297,48±16,29 (O-SI) a 317,86±9,62 (P-L) antes do tratamento clareador e 260,94±17,17 (OSI) a 291,68±16,20 (W-LH, pós-clareamento). Para a microdureza interna as médias variaram de 69,55±42,02 (O-L, 20ìm) a 288,13±53,16 (GC, 80ìm). Na determinação da composição química do esmalte através de ERTF, para o fosfato a média da área do pico de fosfato variou entre 14,50± 0,32 (O-SI) a 14,90 ± 0,28 (P-LH) antes do tratamento, sendo que após o tratamento variaram entre 14,24 ± 0,72 (P-L) a 15,03 ± 0,23 (P-LH). Para o carbonato valores de: 3,60 ± 0,52 (W-LH) a 4,41 ± 0,67 (P-SI) antes do tratamento foram encontrados. Após o tratamento variaram entre: 3,69 ± 0,29 (GC) a 4,41 ± 0,13 (P-LH). A concentração de cálcio presente na solução de enxágüe variou entre 0,32 (W-SI) a 1,61 (O-L). Na microscopia eletrônica de varredura, com exceção do grupo controle, todos os grupos apresentaram alterações morfológicas na superfície. Em microscopia de luz polarizada, os grupos Whiteness sem irradiação, com luz halógena e LED/laser, Pola Office com LED/laser e Opalescence com luz halógena e LED/laser apresentaram desmineralização em profundidade. Observamos alterações no conteúdo mineral pela diminuição significativa dos valores de microdureza, perda de cálcio e desmineralização visualizada em microscopia de luz polarizada, além de alterações morfológicas na superfície do esmalte visualizadas em microscopia eletrônica de varredura. Concluímos que a utilização do peróxido de hidrogênio a 35% empregado no tratamento clareador em consultório requer cautela uma vez que, causa alterações na estrutura do esmalte como mostrado no presente estudo / Abstract: Several studies have been concerned with the adverse effects produced by home applied and in-office bleaching treatments. The aim of this study is to evaluate the effects of highconcentrated bleaching agents (35% hydrogen peroxide) on human enamel microhardness, chemical and structural composition. Sixty and five human third molars human were used. Two enamel blocks (4x4x3mm) were obtained from bucal and lingual surfaces of each tooth. The samples were divided in 10 groups (n=10). Before the bleaching treatment, samples were polished and submitted to microhardness test (Knoop) and Fourier Transform Raman Spectroscopy (FTRS) analysis in order to determine the concentration of phosphate (PO4) and carbonate (CO3) present the enamel. Control group (CG) was not submitted to the bleaching treatment. In the remaining experimental groups three different bleaching agents were used (Whiteness HP Maxx - W; Pola Office ¿ P and Opalescence Xtra - O) and three ways of irradiation (no light irradiation - N; irradiation with halogen light - HL and irradiation with LED + Diode Laser - L). After the treatments, the rinsing water solution was to evaluate the concentration of calcium, by means of atomic absorption spectrometry analysis. Afterwards, the samples were re-submitted to FTRS and to surface and cross-sectional microhardness measurement. Samples were observed in scanning electron microscopy to observe surface alterations and in polarized light microscopy to examine the effects of the bleaching techniques in the demineralization of the enamel. The average surface microhardness values microhardness ranged from 297.48±16.29 (O-N) to 317.86±9.62 (P-L) before the bleaching treatment and 260.94±17.17 (O-N) to 291.68±16.20 (W-HL) after bleaching. The mean values obtained after cross-sectional microhardness measurement ranged from 69.55±42.02 (O-L, 20µm) to 288.13±53.16 (CG, 80 µm). The phosphate concentration on enamel determined by means of FTRS ranged from 14.50±0.32 (O-N) to 14.90±0.28 (P-HL) before the treatment. After the treatment the phosphate concentration ranged from 14.24±0.72 (P-L) to 15.03±0.23 (P-HL). The concentration of carbonate present on treated enamel ranged from 3.60±0.52 (WHL) to 4.41±0.67 (P-N) before the treatment and after the treatment, the concentration varied from 3.69±0.29 (CG) to 4.41±0.13 (P-LH). The concentration of calcium in the rinsing water solution ranged from 0.32 (W-N) to 1.61 (O-L). The scanning electron microscopy showed that all groups presented morphologic alterations in the surface, except for the control group. The images obtained after polarized light microscopy showed that Whiteness without irradiation, with halogen light and LED/diode laser, Pola Office with LED/diode laser and Opalescence with halogen light and LED/diode laser presented demineralization. Alterations on enamel mineral content, significant decrease of enamel microhardness and calcium concentration, demineralization observed by means of polarized light microscopy and morphological alterations on enamel observed by means of scanning electron microscopy were observed in the present study. In conclusion, the use of the 35% hydrogen peroxide as a bleaching agent in clinical situations requires caution, since it may cause alterations on enamel structure as observed in the present study / Mestrado / Mestre em Materiais Dentários

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/287820
Date02 August 2007
CreatorsBerger, Sandrine Bittencourt
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Giannini, Marcelo, 1969-, Filho, Leonardo Eloy Rodrigues, Sinhoreti, Mário Alexandre Coelho
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Materiais Dentários
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format120p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.126 seconds