Impact of Overmodulation Methods on Inverter and Machine Losses in Voltage-Fed Induction Motor Drives

The modulation methods Space Vector PWM (SVPWM), Discontinuous PWM (DPWM1, DPWMMAX) and six-step mode are investigated in the overmodulation range of a voltage-fed induction motor drive. This area enables an increase of inverter output voltage so that drive performance can be enhanced. Though, pulse dropping occurs which results in increased iron losses and current waveform quality
degradation. Due to differences in harmonic distortion the modulation methods cause various torque oscillations and power losses in induction motors and inverter drives. To quantify these effects in a squirrel cage induction motor drive a simulation model containing a finite element machine model and an analytic inverter model is developed, in order to find the PWM scheme offering maximum torque and minimal power losses. Additionally, the holistic investigation of machine and inverter losses allows for making statements concerning total losses of drive systems and the most suitable overmodulation scheme for the application.

Identiferoai:union.ndltd.org:DRESDEN/oai:qucosa:de:qucosa:86851
Date15 August 2023
CreatorsMahlfeld, Hannes, Schuhmann, Thomas, Döbler, Ralf, Cebulski, Bernd
PublisherIEEE
Source SetsHochschulschriftenserver (HSSS) der SLUB Dresden
LanguageEnglish
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/acceptedVersion, doc-type:conferenceObject, info:eu-repo/semantics/conferenceObject, doc-type:Text
Rightsinfo:eu-repo/semantics/openAccess
Relation10.1109/ICELMACH.2016.7732657