Orientador: Carlos Henrique Ribeiro Camargo / Banca: Cláudio Antonio Talge Carvalho / Banca: Renato Miotto Palo / Resumo: Objetivo: O objetivo deste estudo foi avaliar a influência do tempo de endurecimento sobre as propriedades físicas (teste de push-out) e biológicas (XTT, MNT) de sete cimentos endodônticos: Apexit Plus, Real Seal, Endo Rez, Roeko Seal, AH Plus, Endomethasone N e o cimento biocerâmico iRoot SP. Material e Métodos: Para a análise da citotoxicidade (XTT), foram utilizados fibroblastos do ligamento periodontal humano (PDLF). Para o número de micronúcleos (MNT), este estudo avaliou culturas de células expostas a diluições dos cimentos testados sobre células V79 No teste de push-out foram usados cento e quarenta dentes humanos unirradiculares que tiveram suas coroas removidas. Os canais radiculares foram preparados biomecanicamente com o sistema rotatório Mtwo (VDW GmbH, München, Alemanha) até o número de série 702 a 25 mm (25-40). Durante todo o preparo biomecânico, os canais foram irrigados com 2 ml de hipoclorito de sódio. Os espécimes foram seccionados em fatias de 2 mm nos terços cervical, médio e apical. O teste de Push-out foi realizado a uma velocidade de 1 mm / min e célula de carga de 50 Kgf. Os testes biológicos foram avaliadas após 24 h, 72 h, 1 semana, 1 mês, 3 meses, 6 meses e um ano após a manipulação e o teste de push-out 15 dias e 1 ano.Os dados foram analisados pelo teste de Kruskal-Wallis e teste de Dunn (p = 0,05). Resultados: IRooot SP, Roeko seal, Apexit Plus, AH Plus e Real Seal não mostraram citotoxicidade nas células PDLF. AH Plus, Real Seal, IRooot SP e Endomethasone N não apresentaram genotoxicidade. Roeko Seal e Apexit Plus mostraram ser genotóxico e EndoRez apresentou alta genotoxicidade. Roeko Seal, IRooot SP e EndoRez tiveram menor resistência à tração nos terços apical, médio e cervical, tanto em 15 dias e 1 ano de análise. Além disso, Endomethasone N, Real Seal e AH Plus apresentaram uma força de adesão satisfatória após 1 ano em todos os terços. Conclusão: conclui-se que... / Abstract: Objective: The aim of this study was to evaluate the influence of curing time on physical (push-out test) and biological properties (XTT, MNT) of seven sealers: Apexit Plus, Royal Seal, Endo Rez, Roeko Seal, AH Plus, Endomethasone, and bioceramic cement iRoot SP. Material and Methods: To the citotoxity analysis (XTT), fibroblasts of the human periodontal ligament were used (PDLF). To the number of micronuclei (MNT), this study evaluated cell cultures exposed to dilutions of the tested sealers, among them from causing excessive cytotoxic effects on V79 cells. To push-out test was used one hundred and forty single-rooted teeth which had the crowns removed. The root canals were prepared biomechanically with the rotary system Mtwo (VDW GmbH, München, Alemanha) until to series number 702 to file 25 mm (25-40). Throughout the biomechanical preparation, the canals were irrigated with 2 ml of sodium hypochlorite. The specimens were sectioned in slices of 2 mm in cervical, middle and apical. The push-out test was performed at speed of 1 mm/min and 50 kgf load cell. The tests were evaluated after 24 h, 72 h, 1 week, 1 month, 3 months, 6 months and one year after manipulation. Data were analyzed by Kruskal-Wallis and Dunn test (p = 0.05). Results: IRooot SP, Roeko Seal, Apexit Plus, AH plus and Real Seal showed no cytotoxicity in PDLF cells. AH plus, Real Seal, IRooot SP and Endomethasone N showed no genotoxicity. Roeko Seal and Apexit Plus have shown to be genotoxic and EndoRez showed high genotoxicity. Roeko Seal, IRooot SP and EndoRez had lower bond strength in the apical, middle and cervical thirds in both the 15-day and 1 year analysis. Apexit Plus, Endomethasone N, Real Seal and AH plus had a satisfactory bond strength after 1 year in all thirds. Conclusion: It is conclude that AH plus and Real Seal were the sealer with lower cytotoxicity and genotoxicity, with good values of bond strength in all third, keeping as the material of choice for.... / Mestre
Identifer | oai:union.ndltd.org:UNESP/oai:www.athena.biblioteca.unesp.br:UEP01-000843350 |
Date | January 2014 |
Creators | França, Monique Costa Moreira. |
Contributors | Universidade Estadual Paulista "Julio de Mesquita Filho" Instituto de Ciência e Tecnologia (Campus de São José dos Campos). |
Publisher | São José dos Campos, |
Source Sets | Universidade Estadual Paulista |
Language | Portuguese, Portuguese, Texto em português; resumos em português e inglês |
Detected Language | English |
Type | text |
Format | 112 f. : |
Relation | Sistema requerido: Adobe Acrobat Reader |
Page generated in 0.0016 seconds