Estudo in vitro da biomecânica de prótese fixa implantossuportada por meio da extensometria linear elétrica / In vitro biomechanical study of implant prosthesis fixed by means of linear electrical extensometry

Orientador: Wilkens Aurélio Buarque e Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-20T01:35:28Z (GMT). No. of bitstreams: 1
Ribeiro_LiviaForster_M.pdf: 2135600 bytes, checksum: 328020004d2dfccf85672ad44205aa07 (MD5)
Previous issue date: 2012 / Resumo: Este estudo in vitro teve como objetivo, avaliar as deformações de implantes e componentes protéticos de uma prótese parcial fixa implantossuportada, submetida às cargas axiais por meio da extensometria elétrica. Foi confeccionado um modelo experimental, simulando um hemi-arco desdentado, referente aos elementos 15 ao 18, reabilitados com análogos de implantes osseointegrados, na posição dos elementos 15 e 17, e um corpo de prova simulando uma prótese parcial fixa metálica constituída de liga de Níquel-Cromo (Ni-Cr), com os pônticos localizados nos elementos 16 e 18, sendo este último com extensão em cantilever. Na região cervical dos análogos e cervicais dos pilares, foram fixados quatro extensômetros um em cada face, mesial, distal, vestibular e palatina. No corpo de prova foram fixados quatro extensômetros na cervical da prótese. O corpo de prova foi submetido a um teste de cargas axiais controladas, utilizando o sistema de aquisição de dados AqDados e AqDAnalysis (ADS0500IP- Lynx). Os ensaios mecânicos, com cargas estáticas compressivas axiais de 150N, foram realizados em máquina universal de ensaio DL EMIC 2000 0,5mm/min. Os resultados obtidos neste estudo mostraram que todos os componentes avaliados apresentaram valores consistentes de deformação por compressão e/ou tração, em função do carregamento aplicado (p<0,0001). Desta forma, foi possível concluir que as deformações observadas entre a região cervical do corpo de prova, pilares protéticos e análogos de implantes foram significativamente diferentes entre si (p<0,005 ou p<0,001), e que os fenômenos mecânicos observados foram de natureza deflectiva com características de compressão e tração. As comparações realizadas no plano horizontal mostraram diferenças estatisticamente significantes, na região dos análogos dos implantes, e as comparações realizadas no plano vertical exibiram diferenças significativas entre os componentes do sistema de um dos análogos estudados / Abstract: This study in vitro aimed to evaluate the deformation of implants and prosthetic components of implant-fixed partial denture, subjected to axial loads by means of strain gages. We made an experimental model simulating a hemi-arch edentulous, referring to the elements 15 to 18, similar rehabilitated with osseointegrated implants in the position of the elements 15 and 17, and a sample simulating a fixed partial denture metal alloy consisting of Nickel-Chromium (Ni-Cr), with elements located in pontics 16 and 18, the latter extending in cantilever. In the cervical region of the pillar analogs and neck, four strain gauges were attached one on each side, mesial, distal, buccal and palatal. In the sample have been set in four strain gages neck of the prosthesis, two strain gages under the pontic element and under the region on the cantilever. The sample has been subjected to an axial load controlled test, using the data acquisition system and AqDados AqDAnalysis (ADS0500IP-Lynx). The mechanical tests with static compressive axial 150N, were performed on universal testing machine EMIC DL 2000 0.5 mm / min. The results of this study showed that all components evaluated had consistent values of compression set and / or traction as a function of applied load (P <0.0001). Thus, was possible to conclude that the observed deformations of the cervical region of the body of evidence, pillars and similar prosthetic implants were significantly different (P <0.005 or 0.001), and the mechanical phenomena observed in nature were deflected with characteristics of compression and tension. The comparisons made in the horizontal plane showed statistically significant differences in the analogous region of the implants, and the comparisons made in the vertical plane showed significant differences between the system components of a similar study / Mestrado / Protese Dental / Mestre em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/290264
Date20 August 2018
CreatorsRibeiro, Lívia Forster, 1978-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Silva, Wilkens Aurelio Buarque e, 1967-, Oliveira, Milene de, Ramos, Guilherme da Gama
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format63 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0026 seconds