Return to search

Avaliação dos elementos finitos de tensões no tecido ósseo peri-implantar durante a osseointegração / Finite element analysis of stresses in peri-implant bone tissue during osseointegration

Orientador: Rafael Leonardo Xediek Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T13:50:15Z (GMT). No. of bitstreams: 1
Santos_MateusBertoliniFernandesdos_D.pdf: 5044188 bytes, checksum: b81a4d5dccdc37cad705fb6ddaf4b97c (MD5)
Previous issue date: 2011 / Resumo: Forças aplicadas por próteses totais a implantes submersos durante o período deosseointegração podem, em alguns casos, levar ao insucesso clínico. Até o momento não existe trabalho na literatura que quantifique e/ou verifique a distribuição das forças mastigatórias em implantes submersos durante a ação mastigatória de próteses totais convencionais usadas provisoriamente durante o período de osseointegração. Dessa forma, neste trabalho foram avaliadas as tensões geradas no tecido ósseo subjacente a implantes recém-colocados, em diferentes situações, durante a ação mastigatória em próteses totais convencionais provisórias inferiores, por meio da metodologia dos elementos finitos. Com software de modelagem 3-D (SolidWorks 2010, SolidWorks Corp., Concord, Massachusetts, EUA) foram confeccionados modelos tridimensionais de mandíbula simulando diferentes situações clínicas: (1) implantes submersos, próteses totais convencionais e próteses reembasadas com diferentes materiais reembasadores macios; (2) diferentes níveis de altura de exposição dos cicatrizadores (submerso, nível gengival, 1,5 mm exposto no meio bucal); e (3) diferentes espessuras e comparação entre reembasamento na base da prótese inteira ou somente na região dos implantes. As análises foram realizadas em software específico (ANSYS Workbench 12, Ansys Inc., Canonsburg, Pennsylvania, EUA) e para cada modelo foram simuladas duas situações, com aplicação de carga mastigatória em canino inferior direito (35N) e primeiro molar inferior direito (50N). Todas as análises foram realizadas em tensão máxima principal, em MPa. Os resultados obtidos demonstraram que o reembasamento da prótese com material macio reduziu a concentração de tensões no tecido ósseo peri-implantar, sendo a concentração de tensão diretamente relacionada com a maciez do material. Os cicatrizadores submersos foram os que apresentaram menor valor de concentração de tensões. A espessura e área de reembasamento estão relacionadas à transmissão de tensões ao osso peri-implantar, quando o reembasamento da região dos implantes com espessura de 3 mm apresentou melhores resultados. Comparando-se os resultados mostrados nas diferentes simulações conclui-se que a situação que promoveu menor concentração de tensões no osso peri-implantar foi com implantes submersos, reembasamento realizado somente na região dos implantes, espessura de 3 mm e material macio. / Abstract: Forces applied to submerged implants from complete dentures during the osseointegration period can, in some cases, lead to clinical failure. To date there is no study in the literaturethat quantifies and/or verifies the stress distribution of occlusal forces in submerged implants during the masticatory function of conventional complete dentures used on an interim basis during the period of osseointegration. Thus, this study evaluated the stresses in the bone adjacent to newly placed implants during the masticatory function in conventional complete dentures through the finite element methodology. Using a 3-D modeling software (SolidWorks 2010, SolidWorks Corp., Concord, Massachussets, EUA) it were made tridimensional models of a mandible simulating different clinical situations: (1) submerged implants, conventional complete dentures and relined ones with different soft liner materials; (2) different height levels of exposure to the oral environment (submerged, gingival level and 1.5mm of exposure to the oral environment); and (3) different thickness and comparation between relining the entire base or only in the region near the implants. The analysis were made in a specific software (ANSYS Workbench 12, Ansys Inc., Canonsburg, Pennsylvania, EUA) and for each model it were simulated two situations with masticatory load in inferior right canine (35N) and inferior right first molar (50N). All the analysis were made in maximum principal stress, in MPa. The obtained results showed that relined dentures with soft liner material reduced the stress concentration in the peri-implant bone tissue, being the stress concentration directly related to the softness of the material. Submerged implants presented the lowest values of stress concentration in the peri-implant bone tissue. The thickness and the area of reline are related to the transmission of stress to the peri-implant bone tissue, when relining the denture only in the region of the implants with a 3-mm thick layer of soft liner material presented better results. Comparing the results obtained from the different simulations it is possible to conclude that the situation which promoted fewer stress concentration in the peri-implant bone was with submerged implants, relining made only in the implants region, thicker layer (3 mm) of reline and softer material. / Doutorado / Protese Dental / Doutor em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288549
Date02 September 2011
CreatorsSantos, Mateus Bertolini Fernandes dos, 1985-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Consani, Rafael Leonardo Xediek, 1974-, Marchini, Leonardo, Cavalcanti, Bruno das Neves, Mesquita, Marcelo Ferraz, Henriques, Guilherme Elias Pessanha
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format68 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0054 seconds