Made available in DSpace on 2014-06-11T19:31:02Z (GMT). No. of bitstreams: 0
Previous issue date: 2009-02-06Bitstream added on 2014-06-13T18:41:29Z : No. of bitstreams: 1
vescove_hv_dr_jabo.pdf: 630243 bytes, checksum: b66c2dbcbb17475abf180fe7521ce34a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi analisar o consumo, o custo de energia elétrica e resultado econômico em citros (Citrus sinensis) irrigado. Os tratamentos constaram de sistemas de irrigação do tipo gotejamento, com uma e duas linhas laterais de distribuição de água, microaspersão e um tratamento sem irrigação. Para cada sistema foram utilizadas três lâminas de água; 100%, 75% e 50% da Etc (evapotranspiração da cultura). Foi estudado o custo da energia elétrica para dois grupos tarifários, Grupo A e Grupo B. No grupo A foram determinados os dispêndios com a energia para tarifas Estrutura Binômia Convencional e Horo-Sazonal (verde e azul), além, da tarifa especial para irrigante noturno. Os preços de demanda e kWh dos sistemas tarifários foram obtidos no site CPFL (Companhia Paulista de Força e Luz). A menor relação entre o consumo de energia elétrica por ha (kWh.ha-1) e a produtividade (t) foi obtida nos tratamentos irrigados com 50% da Etc. O sistema tarifário horosazonal verde/azul Grupo A irrigante noturno teve o menor custo de energia. Os tratamentos irrigados com lâmina de 50% apresentaram maiores produtividade em relação à lâmina de 100% da Etc. O maior retorno econômico ocorreu nos tratamentos irrigados com 50% da Etc. / The objective of this work is to analyze the consumption, the electric energy cost, and the economic results in irrigated citros (Citrus sinensis). The procedures used consisted of a dripping equipment, with one and two lateral lines of water distribution, a micro sprinkler as well as a treatment without irrigation. For each system of irrigation, three water depths have been used; 100%, 75% and 50% of Etc (citrus evapotranspiration). The electric energy cost was studied for two tariff groups, Group A and Group B. For the Group A it was determined the expenses with the energy for the tariffs Binômia Structure Convencional and Horo-Sazonal (green and blue), besides the special tariff for nocturnal irrigation. The prices of the kWh tariff were obtained from the CPFL site ( power company of Sao Paulo, Brazil). The best relation between the consumption of electric energy (kWh.ha-1) and the productivity (t.ha-1) occurred when the irrigation is done with 50% of the Etc. The tariff system Horo-Sazonal green and blue of the Group A, with nocturnal irrigation, showed the smaller energy cost. The irrigated treatments with depth of 50% have presented higher productivity than those of 100% of Etc. Higher economical returns are achieved when the treatments irrigated with 50% of the Etc are chosen.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/100850 |
Date | 06 February 2009 |
Creators | Vescove, Humberto Vinicius [UNESP] |
Contributors | Universidade Estadual Paulista (UNESP), Turco, José Eduardo Pitelli [UNESP] |
Publisher | Universidade Estadual Paulista (UNESP) |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis |
Format | vi, 50 f. : il. |
Source | Aleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP |
Rights | info:eu-repo/semantics/openAccess |
Relation | -1, -1 |
Page generated in 0.0019 seconds