Return to search

Fórmula Cockcroft Gault y su relación con la depuración de creatina endógena por método colorimétrico, en gestantes atendidas en el Hospital Nacional Sergio Bernales, Lima - Perú 2015.

Introducción: El método convencional usado para estimar la tasa de filtrado glomerular (TFG) presenta limitaciones y dificultades para las mujeres en periodo de gestación, las cuales presentan alteraciones a nivel renal, pudiendo evolucionar hacia la pre eclampsia, ante esto se espera encontrar en la formula Cockcroft – Gault una alternativa adecuada para estimar y monitorear la TFG en gestantes. Objetivo: Establecer la correlación entre la fórmula Cockcroft – Gault y la depuración de creatinina endógena (DCE) por método colorimétrico en gestantes. Diseño: Correlacional, observacional, prospectivo y corte transversal. Lugar: Laboratorio central, Hospital Nacional Sergio Bernales de Lima, Perú. Participantes: Gestantes ambulatorias. Materiales y métodos: Muestras de sangre y orina de 24 horas de 92 gestantes entre noviembre 2015 y enero 2016. Se utilizó el coeficiente de correlación de Pearson para comparar ambos métodos usados para estimar la TFG. Resultados: El promedio de la DCE colorimétrica fue 73,65 ± 19,85 ml/min, la obtenida por fórmula fue 99,82 ± 18,75 ml/min y la correlación entre dichos métodos de laboratorio en el total de las gestantes fue moderada (r = 0,56). Gestantes del I trimestre tuvieron baja correlación (r = 0,40), las del II trimestre tuvieron moderada correlación (r = 0,67) y las del III trimestre mostraron baja correlación (r = 0,49), todos los casos presentaron diferencia significativa (p < 0,05). Conclusión: Se encontró baja correlación entre la DCE y la fórmula Cockcroft – Gault en gestantes. Palabras claves: tasa de filtrado glomerular, depuración de creatinina endógena colorimétrica, fórmula Cockcroft – Gault, grado de correlación. / --- Introduction: The conventional method used to estimate the glomerular filtration rate (GFR) has limitations and difficulties for women in gestation period, which present alterations to the kidney level and can progress to pre eclampsia, before it is expected to find in the Cockcroft - Gault an adequate alternative to estimate and monitor the GFR in pregnant women. Objective: To establish the correlation between the Cockcroft - Gault and endogenous creatinine clearance (ECC) by colorimetric method in pregnant women. Design: correlational, observational, prospective and cross-sectional. Location: Central Laboratory in Sergio Bernales National Hospital, Lima - Peru. Participants: Pregnant ambulatory women. Materials and Methods: Blood samples and 24-hour urine of 92 pregnant women between November 2015 and January 2016. The Pearson correlation coefficient was used to compare the two methods used to estimate GFR. Results: The average of the ECC Colorimetric was 73.65 ± 19.85 ml / min, obtained by formula was 99.82 ± 18.75 ml / min and the correlation between these laboratory methods in total pregnant women was moderate (r = 0.56). Gestating the first quarter had low correlation (r = 0.40), those of the second quarter had moderate correlation (r = 0.67) and the third quarter showed a low correlation (r = 0.49), all cases showed difference significant (p <0.05). Conclusion: It was found low correlation between the ECC and the Cockcroft – Gault formula in pregnant women. Keywords: glomerular filtration rate, colorimetric endogenous creatinine clearance, Cockcroft - Gault, degree of correlation.

Identiferoai:union.ndltd.org:Cybertesis/oai:cybertesis.unmsm.edu.pe:cybertesis/4849
Date January 2016
CreatorsGolac Malca, Mario Alexander
ContributorsMiguel Hernán Sandoval Vegas
PublisherUniversidad Nacional Mayor de San Marcos
Source SetsUniversidad Nacional Mayor de San Marcos - SISBIB PERU
LanguageSpanish
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/bacherlorThesis
SourceRepositorio de Tesis - UNMSM, Universidad Nacional Mayor de San Marcos
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0017 seconds