Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2017-11-30T11:22:21Z
No. of bitstreams: 1
Cláudio Trindade Scherer_.pdf: 4509704 bytes, checksum: 6adc0f4eb6a2c5abca0aa3ac53dbcea7 (MD5) / Made available in DSpace on 2017-11-30T11:22:22Z (GMT). No. of bitstreams: 1
Cláudio Trindade Scherer_.pdf: 4509704 bytes, checksum: 6adc0f4eb6a2c5abca0aa3ac53dbcea7 (MD5)
Previous issue date: 2017-08-14 / Nenhuma / O conjunto de paredes e portas separadas pela circulação condominial em edifícios residenciais passou a ter seu desempenho acústico avaliado, a partir da entrada em vigor da norma brasileira NBR 15575, que trata do desempenho das edificações. Nesse contexto, esse trabalho propõe determinar a influência das características dos elementos construtivos – portas e circulações entre unidades habitacionais – no isolamento ao ruído aéreo do conjunto de paredes e portas separadas pelo hall de entrada. Primeiramente foi realizado um estudo piloto que envolveu ensaios em campo feitos em diversas obras. Com isso, foram escolhidos três prédios e executados uma série de ensaios de desempenho acústico em campo, abrangendo diversas situações. Também foram usados artifícios para a vedação das frestas das portas, a fim de verificar a melhora do desempenho do sistema. Os resultados obtidos apontam para a perda de desempenho acústico com o aumento das frestas entre a folha da porta e o piso. Foram encontradas também relações com tempo de reverberação dos ambientes de circulação e a distância entre as portas de entrada das unidades habitacionais. / Sets of walls and doors separated by condominium corridors in residential buildings started having their acoustic performance evaluated when the Brazilian standard NBR 15575 came into effect, which concerns the performance of buildings. In this context, this study proposed to determine the influence of the characteristics of constructive elements – doors and corridors between residential units – on the airborne sound insulation of the set of walls and doors separated by the entrance hall. First, a pilot study was conducted based on tests performed on many buildings, but it was noted that a deeper study on the subject would be required. Thereby, three buildings were chosen and a series of acoustic performance tests was executed, covering several situations. Maneuvers for sealing door gaps were used as well, in order to assess the performance gains of the system. The results indicated loss of acoustic performance when there were more gaps between the door leaf and the floor. Moreover, relations were found regarding the reverberation time of the corridors and the distance between the entrance doors of residential units.
Identifer | oai:union.ndltd.org:IBICT/oai:www.repositorio.jesuita.org.br:UNISINOS/6803 |
Date | 14 August 2017 |
Creators | Scherer, Cláudio Trindade |
Contributors | http://lattes.cnpq.br/1555729873996754, Oliveira, Maria Fernanda de |
Publisher | Universidade do Vale do Rio dos Sinos, Programa de Pós-Graduação em Arquitetura e Urbanismo, Unisinos, Brasil, Escola Politécnica |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UNISINOS, instname:Universidade do Vale do Rio dos Sinos, instacron:UNISINOS |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.002 seconds