Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-04-27T13:33:42Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_EstrategiaAtivaDeteccao.pdf: 2813652 bytes, checksum: 9236c5852241046962c0c168aef08ef5 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-05-04T12:41:11Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_EstrategiaAtivaDeteccao.pdf: 2813652 bytes, checksum: 9236c5852241046962c0c168aef08ef5 (MD5) / Made available in DSpace on 2017-05-04T12:41:11Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_EstrategiaAtivaDeteccao.pdf: 2813652 bytes, checksum: 9236c5852241046962c0c168aef08ef5 (MD5)
Previous issue date: 2016-10-27 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho realiza-se o estudo de uma técnica ativa para detecção de ilhamento adequada para aplicação em Sistema Fotovoltaico Conectado à Rede (SFCR). A técnica é baseada na injeção de sinais de testes afetando a sequência negativa de tensão após a situação de ilhamento. São apresentadas definições e explicações sobre o sistema de distribuição de potência e sobre os elementos que pertencem a Geração Distribuída (GD). Regulamentos sobre o funcionamento de inversores e o modelo de célula fotovoltaica são apresentados. Detalha-se o conceito de ilhamento e sua Zona de Não Detecção (ZND) bem como as principais técnicas atuais para sua detecção. É apresentada a técnica de sequência negativa. São desenvolvidas algumas aplicações de instrumentação relacionadas a medição de sequência negativa, inversor senoidal e PLL. São projetados modelos que efetuam a injeção e medição de sequência negativa por meio de um VSI: controlador e filtro. São realizadas simulações para detecção de ilhamento sob condições comuns a SFCR: variação de irradiância e sombreamento de célula; e sob condições comuns em um sistema de potência de distribuição: variação e desbalanceamento de carga. Por fim, o desempenho do método aplicado é validado e comparado. / In this paper, is made a study of a active technique for detection of islanding that is proper for application in Grid-Connected Photovoltaic System (GCPS). The technique is based on injection of testing signals which affect negative-sequence of voltage after islanding case. Definitions and explanations are presented about power distributing system and about the elements which belong to Distributed Generation (DG). Standards about inverter’s function and about model of photovoltaic cell are presented. Details of islanding concept and its Non-Detection Zone (NDZ) as well as main current techniques for its detection are exhibited. It is shown the sequence-negative technique. Some instrumental applications related to negative-sequence measurement, sinusoidal inverter and PLL are developed. Models are designed to accomplish the injection and measurement of negative-sequence through VSI: controller and filter. Simulations were made to detect islanding under ordinary conditions of GCPS: irradiance variation and shading of photovoltaic cell; and under ordinary conditions of a power distribution system: charging variation and unbalanced charge. At last, the applied method performance is validated and compared.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/8297 |
Date | 27 October 2016 |
Creators | CARVALHO, Fransérgio Martins |
Contributors | BARRA JUNIOR, Walter |
Publisher | Universidade Federal do Pará, Programa de Pós-Graduação em Engenharia Elétrica, UFPA, Brasil, Instituto de Tecnologia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0022 seconds