Return to search

Avaliação da alteração dimensional de quatro siliconas por condensação através da medição tridimensional por coordenadas / Evaluation of dimensional change of four condensation silicones by three dimensional coordinate measuring

Submitted by Renata Lopes (renatasil82@gmail.com) on 2015-12-03T16:47:38Z
No. of bitstreams: 1
jaianebandolimonteiro.pdf: 2039791 bytes, checksum: c3f28c1a95fdef73d0cc0190a9dfa169 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2015-12-03T21:29:38Z (GMT) No. of bitstreams: 1
jaianebandolimonteiro.pdf: 2039791 bytes, checksum: c3f28c1a95fdef73d0cc0190a9dfa169 (MD5) / Made available in DSpace on 2015-12-03T21:29:38Z (GMT). No. of bitstreams: 1
jaianebandolimonteiro.pdf: 2039791 bytes, checksum: c3f28c1a95fdef73d0cc0190a9dfa169 (MD5)
Previous issue date: 2015-04-30 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo foi avaliar a alteração dimensional dos moldes de silicona por condensação imediatamente, 30min, 1h e 7 dias após a moldagem, com o auxílio da máquina de medição tridimensional por coordenadas. Os grupos foram divididos em: G1: Speedex Putty/Speedex Light Body (Coltene/Vigodent AS Indústria e Comércio), G2: Optosil P Plus/Xantopren L Blue (Heraeus Kulzer GmbH), G3: Zetaplus Putty/Oranwash L (Zhermack SpA) e G4: Precise SX (Dentsply Indústria e Comércio Ltda). Para a obtenção das 80 medições dos 4 materiais (n=20), foi usado um dispositivo composto por uma moldeira perfurada e uma outra parte com 3 edentações pré-estabelecidas. Para a avaliação dimensional, a máquina Crysta-Plus M 574 (Mitutoyo) realizou cada medida 3 vezes nos tempos estabelecidos e obteve-se a média aritmética. A média final das 4 distâncias I, II, III e IV do dispositivo edentado foi novamente aplicada. A análise estatística foi realizada com o teste de Kolmogorov-Smirnov que rejeitou a hipótese nula de distribuição assimétrica. Posteriormente, foi feita a ANOVA para comparar os 4 materiais simultaneamente e o teste paramétrico t de Student para comparar os materiais 2 a 2. O nível de significância global foi de p≤0,05. A maior contração linear foi observada na Speedex, mas não foi significante (p=0,08). A Zetaplus Putty/Oranwash L parece ser a mais estável (p=0,99), mas não foi significante. Não houve diferença estatisticamente significante entre nenhuma silicona por condensação quando comparadas simultaneamente nos 4 tempos ou quando comparadas 2 a 2, à exceção, Precise SX e a Speedex (p=0,05) no tempo T3. Todas as siliconas por condensação testadas apresentam alteração dimensional clinicamente aceitável e podem ser vazadas imediatamente, 30min, 1h e 7 dias após a moldagem. / The purpose was to evaluate the dimensional changes of condensation silicone impressions by immediately, 30min, 1h and 7 days after impression, with the help of threedimensional measuring coordinate machine. The groups were divided in: G1: Speedex Putty/Speedex Light Body (Coltène/Vigodent S/A Ind and Com), G2: Optosil P Plus/Xantopren L Blue (Heraeus Kulzer GmbH), G3: Zetaplus Putty/Oranwash L (Zhermack SpA) and G4: Precise SX (Dentsply Ind and Com Ltda). To obtain 80 measurements of 4 material (n=20) was used a device consisting of a perforated tray and one another part with 3 pre-established indentations. For dimensional evaluation, the Crysta-Plus M574 machine (Mitutoyo) held each measurement 3 times at the established times and obtained the arithmetic mean. The final average of the 4 distances of I, II, III and IV the edentulous device was again applied. Statistical analysis was performed using the Kolmogorov-Smirnov test to reject the null hypothesis of asymmetric distribution. Subsequently, ANOVA was performed to compare the four materials simultaneously and Student's t parametric test to compare the 2 by 2 materials. The overall significance level of p≤0,05. The higher linear contraction was observed in Speedex, but was not significant (p=0,08). The Zetaplus Putty/Oranwash L seems to be more stable (p=0,99) but was not significant. There was no significant difference between any silicone condensation compared simultaneously in 4 times or compared 2 by 2, except, Precise SX and Speedex (p=0,05) in T3 time. All tested condensation silicones exhibit clinically acceptable dimensional change and can be leaked immediately, 30min, 1h and 7 days after impression.

Identiferoai:union.ndltd.org:IBICT/oai:hermes.cpd.ufjf.br:ufjf/87
Date30 April 2015
CreatorsMonteiro, Jaiane Bandoli
ContributorsNetto, Henrique Duque de Miranda Chaves, Salgado, Ivone de Oliveira, Vieira, Jalon de Morais, Oliveira, Milene de
PublisherUniversidade Federal de Juiz de Fora, Programa de Pós-graduação em Clínica Odontológica, UFJF, Brasil, Faculdade de Odontologia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFJF, instname:Universidade Federal de Juiz de Fora, instacron:UFJF
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0026 seconds