Return to search

Avaliação ultrassonográfica quantitativa e qualitativa do canal do carpo em equinos

Made available in DSpace on 2014-08-13T14:50:45Z (GMT). No. of bitstreams: 0
Previous issue date: 2013-06-28Bitstream added on 2014-08-13T18:00:42Z : No. of bitstreams: 1
000755547_20150628.pdf: 250824 bytes, checksum: 795dea93e01fd5ccf15d5ca4b855d266 (MD5) Bitstreams deleted on 2015-06-30T11:22:15Z: 000755547_20150628.pdf,. Added 1 bitstream(s) on 2015-06-30T11:23:08Z : No. of bitstreams: 1
000755547.pdf: 2462293 bytes, checksum: 04864172a4ab96dc6e73edd28ba4e665 (MD5) / O canal do carpo foi avaliado ultrassonograficamente em 60 equinos da raça quarto de milha de corrida, hígidos, em diferentes faixas etárias. Os animais foram divididos em três grupos: potros, adultos jovens e adultos, contendo 10 machos e 10 fêmeas em cada grupo. O objetivo deste estudo foi a caracterização e padronização das estruturas do canal do carpo, pelo exame ultrassonográfico modo B e pelo exame ultrassonográfico Doppler. Dentro do canal do carpo foram avaliados os tendões flexores digitais superficial e profundo, juntamente com o tendão flexor carpo radial. Para cada tendão foi mensurado as dimensões de altura dorso palmar, largura médio lateral e a área dos tendões. Além dos tendões, foram avaliados os nervos palmar medial e palmar lateral, conforme a morfologia normal e a dimensão dorso palmar. No exame ultrassonográfico modo Doppler foram padronizados os índices dopplerfluxométricos das artérias radial e ramo palmar da artéria mediana. Para padronização de ecogenicidade e ecotextura dos tendões foram realizados o histograma. As médias da área do TFDS variaram de 99,20 a 123,20 mm2, do TFDP 114,60 a 143,80 mm2 e o TFCR 17,50 a 24,22 mm2. As médias do diâmetro do retináculo flexor variaram de 1,33 a 1,55 mm, do nervo palmar lateral de 0,93 a 1,09 mm, o do nervo palmar medial 1,10 a 1,44 mm, da artéria radial de 2,54 a 3,06 mm e da artéria palmar medial de 4,23 a 5,47. As médias do índice de resistividade e pulsatilidade da artéria radial variaram de 0,82 a 0,88 e 2,02 a 3,73, respectivamente. As médias do índice de resistividade e pulsatilidade da artéria palmar medial variaram 0,72 a 0,84 e 1,71 a 2,73. Neste estudo foi possível concluir que não ocorreu diferença entre os membros direito e esquerdo para o mesmo animal. Há tendência dos animais adultos apresentaram os tendões maiores e mais heterogêneos do que os adultos jovens e potros. Embora existam diferenças estatísticas entre as ... / The carpal tunnel was sonographically evaluated in 60 quarter horse healthy equines in different age groups, divided into three groups, being these foals, young adults and adults, with 10 males and 10 females in each group. The aim of this study was the characterization and standardization of the structures of the carpal tunnel, through the ultrasound B-mode and the Doppler ultrasonography. Within the carpal tunnel were evaluated superficial digital flexor tendon and deep with the radial carpal flexor tendon. For each tendon was measured the height dimensions dorsal palmar, the medial lateral width and the area of the tendons. Besides the tendons were evaluated the medial palmar nerves and the lateral palmar according to the normal morphology and dorsal palmar dimension. In the Doppler ultrasound were standardized the Dopplerfluxometry indices of the radial arteries and palmar branch of the median artery. For the echogenicity and echotexture standardization of the tendons were performed the histogram. The mean area of the TSDF ranged from 99.20 to 123.20 mm2, of the TDDF from 114.60 to 143.80 mm2 and of the TFCR from 17.50 to 24.22 mm2. The mean diameter of the flexor retinaculum ranged from 1.33 to 1.55 mm, of the lateral palmar nerve from 0.93 to 1.09 mm, of the medial nerve palmar from 1.10 to 1.44 mm, of the artery radial from 2.54 to 3.06 mm and of the medial palmar artery from 4.23 to 5.47. The mean of the resistivity and pulsatility indexes of the radial artery ranged from 0.82 to 0.88 and from 2.02 to 3.73, respectively. The mean resistivity and pulsatility indexes of the medial palmar artery ranged from 0.72 to 0.84 and from 1.71 to 2.73, respectively. The mean resistivity and pulsatility indexes of the medial palmar artery ranged from 0.72 to 0.84 and from 1.71 to 2.73. In this study was concluded that there was no difference between the right and left limbs for the same animal and there is ...

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/108577
Date28 June 2013
CreatorsEvangelista, Felipe Carvalho [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Vulcano, Luis Carlos [UNESP], Machado, Vania Maria de Vasconcelos [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format86 f.
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1, -1

Page generated in 0.0177 seconds