Investigation of Through-Tenon Keys on the Tensile Strength of Mortise and Tenon Joints

A timber frame is a structural building system composed of heavy timber members connected using carpentry-style joinery that may include metal fasteners. A common variant of mortise-and-tenon joints are keyed (or wedged) through-tenon joints. No research on the behavior of wedged joints in timber frames is available. This research provides design knowledge of keyed through-tenon joints from experimental observations and comparisons between mathematical models and experimental measurement. Evaluation of through-tenon keyed mortise and tenon joints was performed by measuring tensile load and stiffness of white oak (Quercus alba) and Douglas-fir (Pseudotsuga menziesii) joints with four- and 11-inch tenons with one and two keys and comparing these results to mathematical models developed from the National Design Specification of Wood Construction (NDS), General Dowel Equations for Calculating Lateral Connection Values (TR-12), and engineering mechanics. Variables included joint species (white oak or Douglas-fir), protruding tenon length (four or 11 inches), and number of keys (one or two). Joints were tested to ultimate load, then model input specimens were cut from tested joints and additional key stock to generate inputs for joint load predictions that were compared to experimental joint load results for validation. Forty joints were tested with white oak keys and six of these joints were retested with ipe (Tabebuia) keys.

Joints with four-inch tenons behaved in a brittle manner with tenon failures. Most joints with 11-inch tenons behaved in a ductile manner with key bending and crushing failures. Joint load and stiffness was similar between white oak and Douglas-fir joints. Joints with 11-inch tenons had greater load and stiffness than with four-inch tenons. Joints with two keys had greater load and stiffness than joints with one key, after normalizing joint load and stiffness responses on key width. Joints retested with ipe keys had greater load than joints originally tested with white oak keys.


Tenon relish (row tear-out) failure was predicted for all joints with four-inch tenons. Horizontal key shearing was predicted for all joints with 11-inch tenons. Ratios of predicted ultimate joint load divided by experimental ultimate joints load (calculated/tested) or C/T ratios were used to validate the models chosen for load prediction. C/T ratios showed that ultimate load model predictions over predicted joint load which was due to occurrence of unpredicted tenon failures and simultaneously occurring key failures where models predicted key failures independently. Design safety factors (DSFs) were developed by dividing experimental ultimate joint load by governing allowable (design) load predictions. C/T ratios and DSFs were most similar between white oak and Douglas-fir joints and most different between joints with one and two keys. Alternative design values (ADVs) were developed for comparison to design load predictions. Comparisons between ADVs and DSFs showed that model predictions were most conservative for joints fastened with denser keys than joint members. / Master of Science

Identiferoai:union.ndltd.org:VTETD/oai:vtechworks.lib.vt.edu:10919/33971
Date19 August 2011
CreatorsShields, Lance David
ContributorsCivil Engineering, Loferski, Joseph R., Hindman, Daniel P., Rojiani, Kamal B.
PublisherVirginia Tech
Source SetsVirginia Tech Theses and Dissertation
Detected LanguageEnglish
TypeThesis
Formatapplication/pdf
RightsIn Copyright, http://rightsstatements.org/vocab/InC/1.0/
RelationShields_LD_T_2011.pdf

Page generated in 0.0017 seconds