Submitted by Silvana Teresinha Dornelles Studzinski (sstudzinski) on 2015-10-26T16:05:56Z
No. of bitstreams: 1
Gabriela Schenkel_.pdf: 3048283 bytes, checksum: cd479115e88afd207554abd627ee1c17 (MD5) / Made available in DSpace on 2015-10-26T16:05:56Z (GMT). No. of bitstreams: 1
Gabriela Schenkel_.pdf: 3048283 bytes, checksum: cd479115e88afd207554abd627ee1c17 (MD5)
Previous issue date: 2015-02 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Os sistemas fotovoltaicos conectados à rede tem como finalidade a conversão da energia solar em energia elétrica. No Brasil, recentemente foi dado o primeiro passo efetivo com a publicação pela ANEEL da Resolução Normativa n° 482. Esta resolução, publicada em 17 de abril de 2012, possibilita à um consumidor doméstico e comercial possuir um sistema de microgeração de energia (hidráulica, solar, eólica, biomassa ou cogeração qualificada) conectado à rede elétrica e fazer compensação de energia. Neste trabalho foi instalado em caráter experimental, no Laboratório de Energias Renováveis da Unisinos, um sistema fotovoltaico conectado à rede com uso de um modelo de microinversor, e buscou-se por meio desta instalação e do monitoramento, analisar o comportamento elétrico e energético do sistema. O sistema é composto por um módulo monocristalino LG255S1C de 255 Wp conectado a um microinversor ENPHASE M215 de 215 W. O período de monitoramento foi de 1° de agosto até 20 de dezembro de 2014. Uma central de aquisição de dados Agilent HP 34970A foi empregada para coletar dados de irradiância no plano do gerador fotovoltaico, corrente e tensão na entrada e saída do microinversor, temperatura de uma célula FV no centro do módulo fotovoltaico e temperatura no dissipador do microinversor. Também foi utilizado como medidor o analisador de energia Fluke 43B, que coleta os dados de potência ativa, potência reativa e potência aparente injetada na rede elétrica pelo sistema. Índices de qualidade de energia como a distorção harmônica total de corrente e fator de deslocamento também foram medidos. A eficiência média diária máxima, considerando a incerteza, medida no microinversor empregado foi de 95,18 % e é semelhante aos valores de eficiência média diária dos microinversores de primeira e segunda geração. O sistema fotovoltaico monitorado com o uso do microinversor atingiu o valor máximo de desempenho global de 0,93. A produção de energia máxima diária em corrente alternada foi de 1,49 kWh. Estima-se, levando em consideração este valor, que a produção mensal pode ser de até 44,7 kWh. Isto significa uma redução de 58 % no consumo de energia em uma residência, levando em consideração o custo de disponibilidade e o sistema instalado em uma residência com consumo médio mensal da região nordeste que é de 120 kWh. / Photovoltaic grid-connected systems aims the conversion of solar energy into electrical energy. In Brazil, was recently given the first effective step with the publication by ANEEL Normative Resolution No. 482. This resolution published on 17 th April, 2012, enables domestic and commercial consumers have an energy microgeneration system (hydro, solar, wind, biomass or qualified cogeneration) connected to mains power and make compensation. In this work was mounted on an experimental character, in the Renewable Energy Laboratory of Unisinos, a photovoltaic grid-connected system that uses a microinverter model, and through this installation and monitoring, analyse the electrical and energetical behavior of the system. The system consists of a 255 Wp LG255S1C monocrystalline module, connected to a 215 W ENPHASE M215 microinverter. The monitoring period was 1 st August to 20 th December, 2014. A central acquisition of Agilent HP 34970A data was used to collect data irradiance in the plane of the PV array, current and voltage at the input and output of microinverter, temperature of a PV cell in the center of the PV module and the microinverter sink. It was also used as a measuring the energy analyzer Fluke 43B, which collects the data of active power, reactive power and apparent power injected into the grid by the system. Power quality indices as the total harmonic current distortion and displacement factor were also measured. The maximum daily average efficiency, considering the uncertainty, measured on the employed microinverter was 95.18 % and is similar than the daily average efficiency values of microinverters of first and second generation. The photovoltaic system monitored using the microinverter peaked overall performance of 0.93. The production maximum daily energy into alternating current was 1.49 kWh. It is estimated taking into account the value that the monthly production can achieved 44.7 kWh. This means a reduction of 58 % in the consumption of a residence considering the availability cost and that the system is installed in a residence with the northest comsumption whose the average monthly consumption is 120.00 kWh.
Identifer | oai:union.ndltd.org:IBICT/oai:www.repositorio.jesuita.org.br:UNISINOS/4909 |
Date | 02 1900 |
Creators | Schenkel, Gabriela |
Contributors | http://lattes.cnpq.br/8233275047450770, Dias, João Batista |
Publisher | Universidade do Vale do Rio dos Sinos, Programa de Pós-Graduação em Engenharia Mecânica, Unisinos, Brasil, Escola Politécnica |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UNISINOS, instname:Universidade do Vale do Rio dos Sinos, instacron:UNISINOS |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0026 seconds